Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Korean LupusPRO: Cross-Cultural validation study for systemic lupus erythematosus

Authors
Han, Jung-YongCho, Soo-KyungNam, EunwooKim, HyoungyoungLee, Shin-SeokJolly, MeenakshiSung, Yoon-Kyoung
Issue Date
Oct-2022
Publisher
SAGE PUBLICATIONS LTD
Keywords
systemic lupus erythematosus; patient-reported outcome; quality of life
Citation
LUPUS, v.31, no.12, pp.1498 - 1507
Indexed
SCIE
SCOPUS
Journal Title
LUPUS
Volume
31
Number
12
Start Page
1498
End Page
1507
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/186181
DOI
10.1177/09612033221122984
ISSN
0961-2033
Abstract
Objective To establish the reliability and validity of the Korean version of LupusPRO version 1.7 (v1.7) for systemic lupus erythematosus (SLE) patients. Methods LupusPRO v1.7 was translated into Korean, followed by pretesting among five native Korean speakers. We administered the LupusPRO v1.7 survey to five SLE patients and made minor changes to clarify the language. Then, 133 SLE patients participated in the validation procedure. In each domain, the internal consistency reliability (ICR) and test-retest reliability (TRR) were assessed using Cronbach's alpha and the intra-class correlation coefficient (ICC), respectively. Criterion validity was evaluated using Spearman's correlation coefficient with the other measures such as SF-36, EQ-5D VAS, and SELENA-SLEDAI PGA. Construct validity was assessed by confirmatory factor analysis (CFA) using the unweighted least square estimation method. Results The mean age of the 133 patients was 36.14 years, and 97% of them were women. Analysis of 130 returned questionnaires revealed that most ICRs of the Korean LupusPRO v1.7 domains were acceptable, with Cronbach's alphas in the range of 0.579-0.949, and most TRRs were good with ICCs from 0.582 to 0.851. Criterion validities presented significant correlations between the LupusPRO v1.7 and other measures validated. In the analysis of the CFA model, the goodness of fit indices demonstrated an acceptable fit. Factor loadings for most individual items were between 0.548 and 0.985. The average variance extracted (AVE) and composite reliability (CR) of most domains were greater than 0.5 and 0.7, respectively, demonstrating acceptable convergent and discriminant validities. Conclusions The Korean version of LupusPRO v.17 had acceptable reliability and validity.
Files in This Item
Appears in
Collections
서울 의과대학 > 서울 내과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Sung, Yoon Kyoung photo

Sung, Yoon Kyoung
COLLEGE OF MEDICINE (DEPARTMENT OF INTERNAL MEDICINE)
Read more

Altmetrics

Total Views & Downloads

BROWSE