Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

The post-renovation indoor environmental quality in a research institute: 3D visualization in the mapopen access

Authors
Lee, Jong-WonLee, Gyu-BaeLee, Seung-EonJeong, Jae-Weon
Issue Date
Jun-2023
Publisher
EDP Sciences
Citation
E3S Web of Conferences, v.396, pp.1 - 7
Indexed
SCOPUS
Journal Title
E3S Web of Conferences
Volume
396
Start Page
1
End Page
7
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/188393
DOI
10.1051/e3sconf/202339601041
ISSN
2555-0403
Abstract
This study aims to evaluate and analyse how a renovation impacts occupant satisfaction through a pre-and post-occupancy evaluation with physical measurements and occupant satisfaction survey. The study was performed for the HVAC renovation of a research institute in Korea. Online occupant survey was conducted in 2021 winter before renovation and in 2022 summer after renovation. Both surveys were performed by using Korean Building Occupant Survey System (K-BOSS) which is integrated building open data including spatial information. The physical measurements through sensors were conducted simultaneously with surveys. In terms of sensor measurement, representative IEQ factors such as temperature, relative humidity, CO2 concentration, and illuminance were measured. The surveys included three main indoor environmental quality categories such as thermal comfort, air quality, lighting environment. The measured results were analysed via T-test. As a result, the study found a statistically significant improvement with HVAC renovation about relative humidity in physical measurements and thermal comfort, air quality, overall occupant satisfaction in the survey. The results are displayed in the 3D (three dimensional) indoor map to help intuitively view gap between pre- and post-occupancy evaluation. Overall, the pre- and post-occupation evaluation survey analyses supported the beneficial effects of IEQ in the renovated building. In conclusion, the study provides a thorough examination of the effect on occupant satisfaction with IEQ of the data-driven changes collected from pre- and post-occupancy evaluation surveys.
Files in This Item
Appears in
Collections
서울 공과대학 > 서울 건축공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jeong, Jae Weon photo

Jeong, Jae Weon
COLLEGE OF ENGINEERING (SCHOOL OF ARCHITECTURAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE