Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Long-term effect of corneoscleral contact lenses on refractory ocular surface diseases

Authors
Lee, Sang-MokKim, Yu JeongChoi, Se HyunOh, Joo YounKim, Mee Kum
Issue Date
Aug-2019
Publisher
ELSEVIER SCIENCE BV
Keywords
Corneoscleral; Contact lens; Stevens-Johnson syndrome; Graft-versus-host disease; Epitheliopathy
Citation
CONTACT LENS & ANTERIOR EYE, v.42, no.4, pp.399 - 405
Indexed
SCIE
SCOPUS
Journal Title
CONTACT LENS & ANTERIOR EYE
Volume
42
Number
4
Start Page
399
End Page
405
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/189472
DOI
10.1016/j.clae.2018.10.011
ISSN
1367-0484
Abstract
Purpose: To report the therapeutic effect of corneoscleral contact lenses (CLs) with a diameter of 14.0 mm on the refractory ocular surface diseases.,Methods: Medical records of 13 eyes (of nine patients) attempted for fitting with corneoscleral CLs for the management of the severe refractory ocular surface diseases were retrospectively reviewed including Stevens-Johnson syndrome (SJS; eight eyes) and chronic ocular graft-versus-host disease (GVHD; five eyes). Lenses were fitted to improve refractory punctate epithelial erosions (PEE, ten eyes) and persistent epithelial defect (PED, three eyes with SJS) despite the proper medical management. Short-term (1 month) and long-term (12 months) changes in the best corrected visual acuity (BCVA), corneal fluorescein staining (CFS) score, mean wearing time, and National Eye Institute's Visual Function Questionnaire-25 (VFQ-25) were evaluated.,Results: Of the 13 eyes, ten eyes were successfully fitted with the corneoscleral CLs. The fitting was failed in three eyes due to small palpebral fissure and shortened fornices (two eyes) and handling difficulty (one eye). At one-month follow-up after successful fitting in ten eyes, mean wearing time was 12.6 h (6.5-17, all day long) and BCVA improved from 0.56 +/- 0.59 to 0.27 +/- 0.46 in logMAR (P = .018). For the eight well-fitted eyes with refractory PEE, CFS score improved from 7.38 +/- 2.20 to 5.13 +/- 2.48 (P = .024). PED improved in all two eyes which were successfully fitted with corneoscleral CLs (Of the three eyes with PED, one eye failed fitting). At 12-month follow-up, mean wearing time was 11.4 h and the improved BCVA and CFS score were maintained. Furthermore, no adverse events attributable to corneoscleral CLs use occurred.,Conclusion: The corneoscleral CLs with a diameter of 14.0 mm were successfully fitted in ten out of 13 eyes with severe refractory ocular surface diseases and demonstrated therapeutic benefits in the well-fitted eyes. The corneoscleral CL can be an option in the management of severe refractory ocular surface diseases.
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 안과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jeong, Kim Yu photo

Jeong, Kim Yu
COLLEGE OF MEDICINE (DEPARTMENT OF OPHTHALMOLOGY)
Read more

Altmetrics

Total Views & Downloads

BROWSE