Feasibility of epidural temporal interference stimulation for minimally invasive electrical deep brain stimulation: simulation and phantom experimental studies
- Authors
- Lee, Sangjun; 박지민; Choi, Da Som; Lim, Seokbeen; Kwak, Youngjong; Jang, Dong Pyo; Kim, Dong Hwan; Ji, Han Bi; Bin Choy, Young; Im, Chang-Hwan
- Issue Date
- Oct-2022
- Publisher
- Institute of Physics Publishing
- Keywords
- temporal interference stimulation; epidural electrical stimulation; finite element method; optimization; human skull phantom experiment
- Citation
- Journal of Neural Engineering, v.19, no.5, pp 1 - 16
- Pages
- 16
- Indexed
- SCIE
SCOPUS
- Journal Title
- Journal of Neural Engineering
- Volume
- 19
- Number
- 5
- Start Page
- 1
- End Page
- 16
- URI
- https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/189571
- DOI
- 10.1088/1741-2552/ac8503
- ISSN
- 1741-2560
1741-2552
- Abstract
- Objective. Temporal interference stimulation (TIS) has shown the potential as a new method for selective stimulation of deep brain structures in small animal experiments. However, it is challenging to deliver a sufficient temporal interference (TI) current to directly induce an action potential in the deep area of the human brain when electrodes are attached to the scalp because the amount of injection current is generally limited due to safety issues. Thus, we propose a novel method called epidural TIS (eTIS) to address this issue; in this method, the electrodes are attached to the epidural surface under the skull. Approach. We employed finite element method (FEM)-based electric field simulations to demonstrate the feasibility of eTIS. We first optimized the electrode conditions to deliver maximum TI currents to each of the three different targets (anterior hippocampus, subthalamic nucleus, and ventral intermediate nucleus) based on FEM, and compared the stimulation focality between eTIS and transcranial TIS (tTIS). Moreover, we conducted realistic skull-phantom experiments for validating the accuracy of the computational simulation for eTIS. Main results. Our simulation results showed that eTIS has the advantage of avoiding the delivery of TI currents over unwanted neocortical regions compared with tTIS for all three targets. It was shown that the optimized eTIS could induce neural action potentials at each of the three targets when a sufficiently large current equivalent to that for epidural cortical stimulation is injected. Additionally, the simulated results and measured results via the phantom experiments were in good agreement. Significance. We demonstrated the feasibility of eTIS, facilitating more focalized and stronger electrical stimulation of deep brain regions than tTIS, with the relatively less invasive placement of electrodes than conventional deep brain stimulation via computational simulation and realistic skull phantom experiments.
- Files in This Item
-
Go to Link
- Appears in
Collections - 서울 공과대학 > ETC > 1. Journal Articles
- 서울 의생명공학전문대학원 > ETC > 1. Journal Articles

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.