Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Inter-reader reliability of contrast-enhanced ultrasound Liver Imaging Reporting and Data System: a meta-analysis

Authors
Kang, Ji HunChoi, Sang HyunLee, Ji SungKim, Dong WookJang, Jong Keon
Issue Date
Oct-2021
Publisher
Springer Science and Business Media LLC
Keywords
Hepatocellular carcinoma; Liver; Meta-analysis; Reproducibility of results; Ultrasonography
Citation
ABDOMINAL RADIOLOGY, v.46, no.10, pp.4671 - 4681
Indexed
SCIE
SCOPUS
Journal Title
ABDOMINAL RADIOLOGY
Volume
46
Number
10
Start Page
4671
End Page
4681
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/189649
DOI
10.1007/s00261-021-03169-7
ISSN
2366-004X
Abstract
Purpose: To systematically determine the inter-reader reliability of the contrast-enhanced ultrasound (CEUS) Liver Imaging Reporting and Data System (LI-RADS), with emphasis on its major features for hepatocellular carcinoma (HCC) and LR-M (LI-RADS category M) features for non-HCC malignancy. Methods: MEDLINE, EMBASE, and Cochrane databases were searched from January 2016 to March 2021 to identify original articles reporting the inter-reader reliability of CEUS LI-RADS. Meta-analytic pooled kappa values (κ) were calculated for major features [nonrim arterial-phase hyperenhancement (APHE), mild and late washout], LR-M features (rim APHE, early washout), and LI-RADS categorization using the DerSimonian-Laird random-effects model. Meta-regression analysis was performed to explore any causes of study heterogeneity. Results: Twelve studies with a total of 2862 lesions were included. The meta-analytic pooled κ of nonrim APHE, mild and late washout, rim APHE, early washout, and LI-RADS categorization were 0.73 [95% confidence interval (CI), 0.67 − 0.79], 0.69 (95% CI, 0.54–0.84), 0.54 (95% CI, 0.37–0.71), 0.62 (95% CI, 0.45–0.79), and 0.75 (95% CI, 0.64–0.87), respectively. Compared with the major features, LR-M features had a lower meta-analytic pooled κ. Substantial study heterogeneity was noted in the LI-RADS categorization, and lesion size (p = 0.03) and the homogeneity in reader experience (p = 0.03) were significantly associated with study heterogeneity. Conclusions: CEUS LI-RADS showed substantial inter-reader reliability for major features and LI-RADS categorization, but relatively lower reliability was found for LR-M features. In our opinion, the definitions of imaging features require further refinement to improve the inter-reader reliability of CEUS LI-RADS.
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 영상의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kang, Ji Hun photo

Kang, Ji Hun
COLLEGE OF MEDICINE (DEPARTMENT OF RADIOLOGY)
Read more

Altmetrics

Total Views & Downloads

BROWSE