Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Feasibility study of β-ray detection system for small leakage from reactor coolant system

Full metadata record
DC Field Value Language
dc.contributor.authorJang, Jaeyeong-
dc.contributor.authorJeong, Jae Young-
dc.contributor.authorPark, Junesic-
dc.contributor.authorCho, Junesic-
dc.contributor.authorPak, Kihong-
dc.contributor.authorKim, Yong Kyun-
dc.date.accessioned2023-09-26T09:40:02Z-
dc.date.available2023-09-26T09:40:02Z-
dc.date.created2022-03-07-
dc.date.issued2022-07-
dc.identifier.issn1738-5733-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/191232-
dc.description.abstractBecause existing reactant coolant system (RCS) leakage detection mechanisms are insensitive to small leaks, a real-time, direct detection system with a detection threshold below 0.5 gpm∙hr−1 was studied. A beta-ray detection system using a silicon detector with good energy resolution for beta rays and a low gamma-ray response was proposed. The detection performance in the leakage condition was evaluated through experiments and simulations. The concentration of 16N in the coolant corresponding to a coolant leakage of 0.5 gpm was calculated using the analytic method and ORIGEN-ARP. Based on the concentration of 16N and the measurement of the silicon detector with 90Sr/90Y, the beta-ray count rate was estimated using MCNPX. To evaluate the effect of gamma rays inside the containment building, the signal-to-noise ratio (SNR) was calculated. To evaluate the count rate ratio, the radiation field inside the containment building was simulated using MCNPX, and response evaluation experiments were performed using beta and gamma rays on the silicon detector. The expected beta-ray count rate at 0.5 gpm leakage was 7.26 × 105 counts/sec, and the signal-to-background count rate ratio exceeded 88 for a transport time of 10 s, demonstrating its suitability for operation inside a reactor containment building.-
dc.language영어-
dc.language.isoen-
dc.publisherKorean Nuclear Society-
dc.titleFeasibility study of β-ray detection system for small leakage from reactor coolant system-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Yong Kyun-
dc.identifier.doi10.1016/j.net.2022.01.028-
dc.identifier.scopusid2-s2.0-85124245616-
dc.identifier.wosid000824758100004-
dc.identifier.bibliographicCitationNuclear Engineering and Technology, v.54, no.7, pp.2748 - 2754-
dc.relation.isPartOfNuclear Engineering and Technology-
dc.citation.titleNuclear Engineering and Technology-
dc.citation.volume54-
dc.citation.number7-
dc.citation.startPage2748-
dc.citation.endPage2754-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.identifier.kciidART002859161-
dc.description.journalClass1-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaNuclear Science & Technology-
dc.relation.journalWebOfScienceCategoryNuclear Science & Technology-
dc.subject.keywordPlusIONIZATION-ENERGY-
dc.subject.keywordPlusSILICON-
dc.subject.keywordAuthor16N-
dc.subject.keywordAuthorBeta-ray detector-
dc.subject.keywordAuthorLeakage detection system-
dc.subject.keywordAuthorRCS leakage-
dc.subject.keywordAuthorReactor coolant system-
dc.subject.keywordAuthorUnidentified leakage-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S1738573322000638?via%3Dihub-
Files in This Item
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Yong Kyun photo

Kim, Yong Kyun
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE