Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Fabrication of anti-leakage Hyflon AD/Poly(4-methyl-1-pentene) hollow fiber composite membrane for an extra-corporeal membrane oxygenation (ECMO) systemopen access

Authors
He, TingJin, YinchaoLi, JieSun, ZhaoyunWang, ZhaohuiLi, QingguoChen, RizhiCui, ZhaoliangLee, Young MooDrioli, Enrico
Issue Date
Jan-2023
Publisher
KeAi Communications Co.
Keywords
Anti-leakage; Hemocompatibility; Hyflon AD60; Poly(4-methyl-1-pentene) (PMP)
Citation
Advanced Membranes, v.3, pp.1 - 10
Indexed
SCOPUS
Journal Title
Advanced Membranes
Volume
3
Start Page
1
End Page
10
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/192224
DOI
10.1016/j.advmem.2023.100067
ISSN
2772-8234
Abstract
Extra-corporeal membrane oxygenation (ECMO) systems can perform the roles of the human heart and lungs to realize extra-corporeal oxygenation of blood. This system mainly depends on the gas-blood exchange membrane, the quality of which impacts the oxygenation performance. Currently, the most widely used gas-blood exchange membrane is made of poly(4-methyl-1-pentene) (PMP) hollow fibers. However, plasma leakage often occurs during clinical applications, which decreases the oxygenation performance and the service life and may endanger the patient's life in serious cases. In this work, Hyflon AD/PMP hollow fiber composite membranes were prepared by coating Hyflon AD on the surfaces of PMP hollow fibers to form ultra-thin, dense layers. Compared the plasma leakage time of the composite membrane with that of the pristine PMP membrane, the Hyflon AD60 layer showed great improvement in anti-leakage performance. The Hyflon AD60/PMP hollow fiber composite membrane possessed lower platelet adhesion and protein adhesion than that of the PMP membrane, indicating better blood compatibility of the Hyflon AD60 membrane. Cytotoxicity experiments were conducted to further confirm the biosafety of Hyflon AD60 as a blood contact medical membrane material. Gas permeance and oxygenation performance of the Hyflon AD60/PMP hollow fiber composite membrane were tested to ensure gas exchange efficiency during the gas separation process. Therefore, the optimized Hyflon AD60/PMP hollow fiber composite membrane has potential for clinical use.
Files in This Item
Appears in
Collections
서울 공과대학 > 서울 에너지공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE