Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Efficacy of an artificial neural network algorithm based on thick-slab magnetic resonance cholangiopancreatography images for the automated diagnosis of common bile duct stones

Authors
Hou, Jong-UkPark, Se WooPark, Seon MeePark, Da HaePark, Chan HyukMin, Seonjeong
Issue Date
Dec-2021
Publisher
WILEY
Keywords
Artificial; Bile duct; Magnetic resonance cholangiopancreatography (MRCP); Neural network; Stone
Citation
JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, v.36, no.12, pp 3532 - 3540
Pages
9
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY
Volume
36
Number
12
Start Page
3532
End Page
3540
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/196395
DOI
10.1111/jgh.15569
ISSN
0815-9319
1440-1746
Abstract
Background and Aim Magnetic resonance cholangiopancreatography (MRCP) can accurately diagnose common bile duct (CBD) stones but is laborious to interpret. We developed an artificial neural network (ANN) capable of automatically assisting physicians with the diagnosis of CBD stones. This study aimed to evaluate the ANN's diagnostic performance for detecting CBD stones in thick-slab MRCP images and identify clinical factors predictive of accurate diagnosis. Methods The presence of CBD stones was confirmed via direct visualization through endoscopic retrograde cholangiopancreatography (ERCP). The absence of CBD stones was confirmed by either a negative endoscopic ultrasound accompanied by clinical improvements or negative findings on ERCP. Our base networks were constructed using state-of-the-art EfficientNet-B5 neural network models, which are widely used for image classification. Results In total, 3156 images were collected from 789 patients. Of these, 2628 images from 657 patients were used for training. An additional 1924 images from 481 patients were prospectively collected for validation. Across the entire prospective validation cohort, the ANN achieved a sensitivity, specificity, positive predictive value, negative predictive value, and overall accuracy of 93.03%, 97.05%, 97.01%, 93.12%, and 95.01%, respectively. Similarly, a radiologist achieved a sensitivity, specificity, positive predictive value, negative predictive value, and overall accuracy 91.16%, 93.25%, 93.22%, 90.20%, and 91.68%, respectively. In multivariate analysis, only bile duct diameter > 10 mm (odds ratio = 2.45, 95% confidence interval [1.08-6.07], P = 0.040) was related to ANN diagnostic accuracy. Conclusion Our ANN algorithm automatically and quickly diagnoses CBD stones in thick-slab MRCP images, therein aiding physicians with optimizing clinical practice, such as whether to perform ERCP.
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 내과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE