Modified Cardiovascular Sequential Organ Failure Assessment Score in Sepsis: External Validation in Intensive Care Unit Patientsopen accessModified Cardiovascular Sequential Organ Failure Assessment Score in Sepsis: External Validation in Intensive Care Unit Patients
- Other Titles
- Modified Cardiovascular Sequential Organ Failure Assessment Score in Sepsis: External Validation in Intensive Care Unit Patients
- Authors
- Ko, Byuk Sung; Ryoo, Seung Mok; Han, Eunah; Chang, Hyunglan; Yune, Chang June; Lee, Hui Jai; Suh, Gil Joon; Choi, Sung-Hyuk; Chung, Sung Phil; Lim, Tae Ho; Kim, Won Young; Sohn, Jang Won; Jeong, Mi Ae; Hwang, Sung Yeon; Shin, Tae Gun; Kim, Kyuseok
- Issue Date
- Dec-2023
- Publisher
- 대한의학회
- Keywords
- Mortality; Organ Dysfunction Scores; Sepsis; Severity of Illness Index
- Citation
- Journal of Korean Medical Science, v.38, no.50, pp 1 - 12
- Pages
- 12
- Indexed
- SCIE
SCOPUS
KCI
- Journal Title
- Journal of Korean Medical Science
- Volume
- 38
- Number
- 50
- Start Page
- 1
- End Page
- 12
- URI
- https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/196612
- DOI
- 10.3346/jkms.2023.38.e418
- ISSN
- 1011-8934
1598-6357
- Abstract
- BACKGROUND: There is a need to update the cardiovascular (CV) Sequential Organ Failure Assessment (SOFA) score to reflect the current practice in sepsis. We previously proposed the modified CV SOFA score from data on blood pressure, norepinephrine equivalent dose, and lactate as gathered from emergency departments. In this study, we externally validated the modified CV SOFA score in multicenter intensive care unit (ICU) patients. METHODS: A multicenter retrospective observational study was conducted on ICU patients at six hospitals in Korea. We included adult patients with sepsis who were admitted to ICUs. We compared the prognostic performance of the modified CV/total SOFA score and the original CV/total SOFA score in predicting 28-day mortality. Discrimination and calibration were evaluated using the area under the receiver operating characteristic curve (AUROC) and the calibration curve, respectively. RESULTS: We analyzed 1,015 ICU patients with sepsis. In overall patients, the 28-day mortality rate was 31.2%. The predictive validity of the modified CV SOFA (AUROC, 0.712; 95% confidence interval [CI], 0.677-0.746; P < 0.001) was significantly higher than that of the original CV SOFA (AUROC, 0.644; 95% CI, 0.611-0.677). The predictive validity of modified total SOFA score for 28-day mortality was significantly higher than that of the original total SOFA (AUROC, 0.747 vs. 0.730; 95% CI, 0.715-0.779; P = 0.002). The calibration curve of the original CV SOFA for 28-day mortality showed poor calibration. In contrast, the calibration curve of the modified CV SOFA for 28-day mortality showed good calibration. CONCLUSION: In patients with sepsis in the ICU, the modified SOFA score performed better than the original SOFA score in predicting 28-day mortality.
- Files in This Item
-
- Appears in
Collections - 서울 의과대학 > 서울 마취통증의학교실 > 1. Journal Articles
- 서울 의과대학 > 서울 내과학교실 > 1. Journal Articles
- 서울 의과대학 > 서울 응급의학교실 > 1. Journal Articles

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.