Evaluating the intake plugging effects on the electrical submersible pump (ESP) operating conditions using nodal analysisopen access

Authors
Iranzi, JosephWang, JihoonLee, YoungsooSon, Hanam
Issue Date
Apr-2024
Publisher
Springer Verlag
Keywords
Electrical submersible pump (ESP); Intake plugging factor; Nodal analysis; Rate-derating factor
Citation
Journal of Petroleum Exploration and Production Technology, v.14, no.4, pp 1071 - 1083
Pages
13
Indexed
SCIE
SCOPUS
Journal Title
Journal of Petroleum Exploration and Production Technology
Volume
14
Number
4
Start Page
1071
End Page
1083
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/197998
DOI
10.1007/s13202-024-01754-2
ISSN
2190-0558
2190-0566
Abstract
The intake plugging of an electrical submersible pump (ESP) has presented a formidable challenge to conventional ESP wells. Attention to cumulative solid deposition is essential since it intensifies the intake plugging severity and impedes ESP performance. We present a new approach to evaluate the ESP performance degradation during increased intake plugging severity. In particular, we employ the intake plugging factor, rate-derating factor, and affinity law to calculate the new ESP speed at different plugging conditions. We used Schlumberger PIPESIM software to perform nodal analysis of the newly calculated ESP speed. The result was validated using the actual field data and compared to the field cases that reported the intake plugging issue. The nodal analysis showed a steady maximum ESP head with zero rate derating at the shut-in point. The intake plugging factor caused a significant reduction in the ESP operating rate and increased pump intake pressure and annulus liquid level. Based on the existing intake plugging field data, we established the quantitative standard for the normal and abnormal intake plugging factor range. The observed results agreed with the field downhole data recorded during the intake plugging problem. We identified that regulating the ESP speed to the reduced operating rate could minimize unexpected pump stoppage. It is also possible to carefully monitor the intake plugging problem by combining the annulus liquid level, the signature of pump intake pressure, and a deadhead test.
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 자원환경공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Wang, Jihoon photo

Wang, Jihoon
COLLEGE OF ENGINEERING (DEPARTMENT OF EARTH RESOURCES AND ENVIRONMENTAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE