가스터빈 노즐 베인의 열전달 예측을 위한 벽면처리법 비교연구Comparative study of near-wall treatment methods for prediction of heat transfer over gas turbine nozzle guide vane
- Other Titles
- Comparative study of near-wall treatment methods for prediction of heat transfer over gas turbine nozzle guide vane
- Authors
- Bak, Jeonggyu; Kim, Jinuk; Lee, Seawook; Gang, Youngseok; Cho, Leesang; Cho, Jinsoo
- Issue Date
- Jul-2014
- Publisher
- 대한기계학회
- Keywords
- Conjugate heat transfer; Gas turbine nozzle guide vane; Near-wall treatment Method; Transition model; 가스터빈 노즐 가이드 베인; 벽면처리 방법; 천이모델; 복합열전달
- Citation
- 대한기계학회논문집 B, v.38, no.7, pp 639 - 646
- Pages
- 8
- Indexed
- SCOPUS
KCI
- Journal Title
- 대한기계학회논문집 B
- Volume
- 38
- Number
- 7
- Start Page
- 639
- End Page
- 646
- URI
- https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/202450
- DOI
- 10.3795/KSME-B.2014.38.7.639
- ISSN
- 1226-4881
- Abstract
- 난류모델에서 벽면처리법이 터빈 노즐 베인의 열전달 예측에 미치는 영향을 비교·분석하였다. 본 연구를 위해 NASA의 C3X 터빈 노즐 베인을 사용하였다. 벽함수 방법, 저레이놀즈수 방법, 천이모델을 사용하여 베인 표면에서의 압력 및 온도를 해석하였다. 해석 결과 터빈 노즐 베인의 중간 압력분포는 각 벽면처리법에 따른 차이 없이 실험값과 잘 일치하였다. 그러나 터빈 노즐 베인의 온도와 열전달 계수는 각 벽면처리법에 따라 큰 차이를 보였다. 전반적으로 저레이놀즈수 방법과 천이모델은 벽함수 방법에 비해 온도 및 열전달 계수 예측에 특별한 이점을 보이지 않았으며, 벽함수 방법을 적용한 레이놀즈응력 난류모델이 터빈 노즐 베인 표면의 온도 및 열전달 계수를 비교적 잘 예측하였다.
The comparative analysis of near-wall treatment methods that affect the prediction of heat transfer over the gas turbine nozzle guide vane were presented. To achieve this objective, wall-function and low Reynolds number methods, and the transition model were applied and simulated using NASA's C3X turbine vane. The predicted turbine vane surface pressure distribution data using the near-wall treatment methods were found to be in close agreement with experimental data. However, the predicted vane metal temperature and heat transfer coefficient displayed significant differences. Overall, the low Reynolds method and transition model did not offer specific advantages in the prediction of temperature and heat transfer than did the wall-function method. The Reynolds stress model used along with the wall-function method resulted in a relatively high accuracy of prediction of the vane metal temperature and heat transfer coefficient.
- Files in This Item
-
Go to Link
- Appears in
Collections - 서울 공과대학 > 서울 기계공학부 > 1. Journal Articles

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.