Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Performance Improvement of a Closed-Conduit UV Reactor by Asymmetric Lamp Positioning using CFD

Authors
Sultan, TipuCho, LeesangCho, Jin Soo
Issue Date
Oct-2014
Publisher
Institute of Fluid Science, Tohoku University
Citation
Eleventh International Conference on Flow Dynamics, pp 564 - 565
Pages
2
Indexed
OTHER
Journal Title
Eleventh International Conference on Flow Dynamics
Start Page
564
End Page
565
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/202594
Abstract
The performance of a closed-conduit ultraviolet (UV) reactor was improved by changing the lamp positions from symmetric to asymmetric. This goal was achieved by incorporating the performance factor reduction equivalent dose(RED). The fluence rate modeling was performed by using UVCalc3D. The results of the four asymmetric cases were compared with the symmetric one. The asymmetric lamp presented can be useful for UV reactor design and optimization. The simulation results provide detailed information about the model configuration and RED. The RED value was increased by approximately 15% for the UVCalc3D model.