Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

경구기관삽관 시 기관삽관 기구에 따른 경추 움직임 비교: 마네킨 예비 연구Comparison of Cervical Spine Movement by Airway Equipment during Orotracheal Intubation: A Manikin Pilot Study

Other Titles
Comparison of Cervical Spine Movement by Airway Equipment during Orotracheal Intubation: A Manikin Pilot Study
Authors
이상현최혁중강형구강보승임태호
Issue Date
Dec-2010
Publisher
대한중환자의학회
Keywords
cervical vertebra; intubation; laryngoscope
Citation
Acute and Critical Care, v.25, no.4, pp 230 - 234
Pages
5
Indexed
KCICANDI
Journal Title
Acute and Critical Care
Volume
25
Number
4
Start Page
230
End Page
234
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/203369
DOI
10.4266/kjccm.2010.25.4.230
ISSN
2586-6052
2586-6060
Abstract
Background: In patients with limited cervical spine movement, equipment for orotracheal intubation should achieve sufficient laryngeal exposure with the least cervical spine movement. This study was designed to compare movement of the cervical spine during the orotracheal intubation with various intubating equipment. Methods: Twelve emergency physicians & residents with a total experience of >50 cases of endotracheal intubation in two emergency centers were assigned to perform orotracheal intubation with four different airway devices,including the Macintosh laryngoscope (ML), DCI video laryngoscope (DCI), Airway Scope (AWS) and Levitan Scope (LS), using the same manikin (AmbuⓇ airway management trainer) in random sequences. Movement of the C-spine was examined by measuring the angle formed by two lines which are parallel to the anterior surface of the C2 and C7 vertebrae bodies. The angle was measured when Cormack-Lehane grade II glottis exposure was achieved during intubation. Results: Mean cervical spine movements were 37.6 ± 9.2o, 32.2 ± 14.2o, 32.2 ± 6.45o and 17.4 ± 10.0o with the ML, DCI (p = 0.347), AWS (p = 0.094), and LS (p < 0.001), respectively, compared to that of ML. Cervical spine movement by LS was 54% less than that by ML. LS produced less cervical spine movement in comparison to DCI (p = 0.013) and AWS (p = 0.001). Conclusions: The Levitan Scope produced less movement of the cervical spine when compared to the Macintosh laryngoscope, DCI video-laryngoscope and Airway Scope during orotracheal intubation in a single airway training manikin model.
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 응급의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kang, Bo Seung photo

Kang, Bo Seung
서울 의과대학 (DEPARTMENT OF EMERGENCY MEDICINE)
Read more

Altmetrics

Total Views & Downloads

BROWSE