Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

A Randomized Controlled Trial of Guided Bone Regeneration for Peri-Implant Dehiscence Defects with Two Anorganic Bovine Bone Materials Covered by Titanium Meshesopen access

Authors
Lim, JaeHyungJun, Sang HoTallarico, MarcoPark, Jun-BeomPark, Dae-HoHwang, Kyung-GyunPark, Chang-Joo
Issue Date
Aug-2022
Publisher
MDPI
Keywords
bone substitutes; clinical research; clinical trials; CT imaging; guided tissue regeneration; bone regeneration; surgical techniques
Citation
MATERIALS, v.15, no.15, pp 1 - 12
Pages
12
Indexed
SCIE
SCOPUS
Journal Title
MATERIALS
Volume
15
Number
15
Start Page
1
End Page
12
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/203481
DOI
10.3390/ma15155294
ISSN
1996-1944
1996-1944
Abstract
The aim of this study is to compare two low-temperature sintered anorganic bovine bone materials (ABBMs), Bio-Oss (Geistlich, Wolhusen, Switzerland) and A-Oss (Osstem, Seoul, Korea), for GBR in dehiscence defects. A single implant was placed simultaneously with GBR in the buccal or bucco-proximal osseous defect by double-layering of inner allograft and outer ABBM, covered by a preformed ultrafine titanium mesh and an absorbable collagen membrane. Grafted volume changes were evaluated by cone-beam computed tomography, taken preoperatively (T0), immediately after implant surgery (T1), after re-entry surgery (T2), and after delivery of the final restoration (T3). The density of the regenerated bone was assessed by measuring the probing depth on the buccal mid-center of the mesh after removing the mesh at T2. Postoperative sequelae were also recorded. Grafted volume shrinkage of 46.0% (0.78 +/- 0.37 cc) and 40.8% (0.79 +/- 0.33 cc) in the Bio-Oss group (8 patients) and A-Oss group (8 patients), respectively, was observed at T3 (p < 0.001). There were no significant differences in grafted volume changes according to time periods or bone density between the two groups. Despite postoperative mesh exposure (3 patients), premature removal of these exposed meshes and additional grafting was not necessary, and all implants were functional over the 1-year follow-up period. Both ABBMs with titanium meshes showed no significant difference in the quantity and density of the regenerated bone after GBR for peri-implant defects.
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 치과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Hwang, Kyung Gyun photo

Hwang, Kyung Gyun
서울 의과대학 (DEPARTMENT OF DENTISTRY)
Read more

Altmetrics

Total Views & Downloads

BROWSE