Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Understanding the different effects of fouling mechanisms on working and reference electrodes in fast-scan cyclic voltammetry for neurotransmitter detection

Authors
Jang, JaehyunCho, Hyun-U.Hwang, SangmunKwak, YoungjongKwon, HaeunHeien, Michael L.Bennet, Kevin E.Oh, YoonbaeShin, HojinLee, Kendall H.Jang, Dong Pyo
Issue Date
May-2024
Publisher
Royal Society of Chemistry
Citation
Analyst, v.149, no.10, pp 3008 - 3016
Pages
9
Indexed
SCIE
SCOPUS
Journal Title
Analyst
Volume
149
Number
10
Start Page
3008
End Page
3016
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/206776
DOI
10.1039/d3an02205f
ISSN
0003-2654
1364-5528
Abstract
Fast-scan cyclic voltammetry (FSCV) is a widely used technique for detecting neurotransmitters. However, electrode fouling can negatively impact its accuracy and sensitivity. Fouling refers to the accumulation of unwanted materials on the electrode surface, which can alter its electrochemical properties and reduce its sensitivity and selectivity. Fouling mechanisms can be broad and may include biofouling, the accumulation of biomolecules on the electrode surface, and chemical fouling, the deposition of unwanted chemical species. Despite individual studies discussing fouling effects on either the working electrode or the reference electrode, no comprehensive study has been conducted to compare the overall fouling effects on both electrodes in the context of FSCV. Here, we examined the effects of biofouling and chemical fouling on the carbon fiber micro-electrode (CFME) as the working electrode and the Ag/AgCl reference electrode with FSCV. Both fouling mechanisms significantly decreased the sensitivity and caused peak voltage shifts in the FSCV signal with the CFME, but not with the Ag/AgCl reference electrode. Interestingly, previous studies have reported peak voltage shifts in FSCV signals due to the fouling of Ag/AgCl electrodes after implantation in the brain. We noticed in a previous study that energy-dispersive spectroscopy (EDS) spectra showed increased sulfide ion concentration after implantation. We hypothesized that sulfide ions may be responsible for the peak voltage shift. To test this hypothesis, we added sulfide ions to the buffer solution, which decreased the open circuit potential of the Ag/AgCl electrode and caused a peak voltage shift in the FSCV voltammograms. Also, EDS analysis showed that sulfide ion concentration increased on the surface of the Ag/AgCl electrodes after 3 weeks of chronic implantation, necessitating consideration of sulfide ions as the fouling agent for the reference electrodes. Overall, our study provides important insights into the mechanisms of electrode fouling and its impact on FSCV measurements. These findings could inform the design of FSCV experiments, with the development of new strategies for improving the accuracy and reliability of FSCV measurements in vivo. The distinct impacts of fouling mechanisms on a carbon fiber microelectrode and an Ag/AgCl reference electrode, affecting their performance in neurotransmitter detection via Fast-scan Cyclic Voltammetry.
Files in This Item
Go to Link
Appears in
Collections
서울 의생명공학전문대학원 > ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jang, Dong Pyo photo

Jang, Dong Pyo
GRADUATE SCHOOL OF BIOMEDICAL SCIENCE AND ENGINEERING (서울 생체의공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE