Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparative Study on Electromagnetic Performance of Slotted and Slotless PM Synchronous Motors According to Aspect Ratios

Full metadata record
DC Field Value Language
dc.contributor.authorHong, Hyeonbin-
dc.contributor.authorLee, Jae-Kwang-
dc.contributor.authorJung, Dong-Hoon-
dc.contributor.authorLee, Ju-
dc.contributor.authorKim, Hyunwoo-
dc.date.accessioned2025-06-25T05:00:07Z-
dc.date.available2025-06-25T05:00:07Z-
dc.date.issued2025-06-
dc.identifier.issn0018-9464-
dc.identifier.issn1941-0069-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/207898-
dc.description.abstractPermanent magnet synchronous motors (PMSMs) are widely used in industrial applications due to their high torque density. PMSM are generally classified into slotted and slotless types, each offering distinct advantages. A key design parameter of PMSM is the aspect ratio, defined as the ratio of the stator outer diameter to the stack length, which significantly affects electromagnetic performance and application suitability. In this paper, a comparative study of 1.35kW slotted and slotless PMSM is proposed based on aspect ratios under the same volume, using a finite element analysis (FEA). Although the volume of PMSM primarily determines electromagnetic performance, such as electromagnetic torque and loss, the aspect ratio is also crucial because of its impact on magnetic leakage flux. Constraints, including the volume of PMSM, magnet thickness, and current density, are selected to compare electromagnetic performances based on aspect ratio. Optimal models of slotted and slotless PMSM are designed, and their electromagnetic performances are compared. The optimal slotless PMSM achieves a torque ripple approximately 31.08%p lower than that of the optimal slotted PMSM. Furthermore, the total harmonic distortion (THD) of the induced voltage is reduced by approximately 20.16%p. To verify this study, the 1.35kW optimal slotless PMSM is manufactured and experimentally tested, showing errors of less than 5% compared to FEA results.-
dc.format.extent4-
dc.language영어-
dc.language.isoENG-
dc.publisherInstitute of Electrical and Electronics Engineers-
dc.titleComparative Study on Electromagnetic Performance of Slotted and Slotless PM Synchronous Motors According to Aspect Ratios-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1109/TMAG.2025.3545821-
dc.identifier.scopusid2-s2.0-85219088603-
dc.identifier.wosid001499319000010-
dc.identifier.bibliographicCitationIEEE Transactions on Magnetics, v.61, no.6, pp 1 - 4-
dc.citation.titleIEEE Transactions on Magnetics-
dc.citation.volume61-
dc.citation.number6-
dc.citation.startPage1-
dc.citation.endPage4-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryEngineering, Electrical & Electronic-
dc.relation.journalWebOfScienceCategoryPhysics, Applied-
dc.subject.keywordPlusMACHINES-
dc.subject.keywordPlusDESIGN-
dc.subject.keywordAuthorAspect ratio-
dc.subject.keywordAuthorelectromagnetic performances-
dc.subject.keywordAuthorfinite element analysis-
dc.subject.keywordAuthorpermanent magnet synchronous motor (PMSM)-
dc.subject.keywordAuthorslotless PMSM-
dc.subject.keywordAuthorslotted PMSM-
dc.identifier.urlhttps://ieeexplore.ieee.org/document/10904917-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 전기공학전공 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Ju photo

Lee, Ju
COLLEGE OF ENGINEERING (MAJOR IN ELECTRICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE