Cited 0 time in
Groove Loss Time: A Novel Wound Leakage Test for Sutureless Clear Corneal Cataract Wound Incision
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Hwang, Sunjin | - |
| dc.contributor.author | Kim, Moonsu | - |
| dc.contributor.author | Yoon, Jooyoung | - |
| dc.contributor.author | Hong, Eun Hee | - |
| dc.contributor.author | Shin, Yong Un | - |
| dc.contributor.author | Kang, Min Ho | - |
| dc.date.accessioned | 2025-07-21T06:00:11Z | - |
| dc.date.available | 2025-07-21T06:00:11Z | - |
| dc.date.issued | 2025-06 | - |
| dc.identifier.issn | 2077-0383 | - |
| dc.identifier.issn | 2077-0383 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/208294 | - |
| dc.description.abstract | Background: This study introduces a novel quantitative method-groove loss time (GLT)-to objectively assess wound leakage following cataract surgery. Methods: In this prospective, single-center study, 70 eyes of 70 patients undergoing cataract surgery via CCI were enrolled. Wound sealing was evaluated by measuring the GLT, defined as the duration the stromal groove remains visible after corneal hydration. GLT was categorized into five grades: 'water-tight' (>10 s), 'excellent' (>5 s), 'good' (3-5 s), 'bad' (1-2 s), and 'poor' (<1 s). Intraocular pressure (IOP) was recorded at four time points: preoperatively, immediately post-surgery, 3-4 h postoperatively, and on postoperative day one. In select cases, anterior segment optical coherence tomography (AS-OCT) was used to confirm wound architecture. Results: All patients demonstrated a GLT longer than 5 s, corresponding to water-tight or excellent wound sealing. Mean IOP values were 16.08 +/- 3.61 mmHg preoperatively, 29.48 +/- 11.13 mmHg immediately post-surgery, 16.38 +/- 5.45 mmHg at 3-4 h, and 16.65 +/- 4.36 mmHg on the day after surgery. No cases of postoperative endophthalmitis, anterior chamber loss, or hypotony were observed. Conclusions: The GLT method provides a simple, objective, and effective tool for evaluating wound integrity in CCIs, ensuring optimal sealing and enhancing postoperative safety. | - |
| dc.format.extent | 10 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | MDPI AG | - |
| dc.title | Groove Loss Time: A Novel Wound Leakage Test for Sutureless Clear Corneal Cataract Wound Incision | - |
| dc.type | Article | - |
| dc.publisher.location | 스위스 | - |
| dc.identifier.doi | 10.3390/jcm14124091 | - |
| dc.identifier.scopusid | 2-s2.0-105009087855 | - |
| dc.identifier.wosid | 001517086500001 | - |
| dc.identifier.bibliographicCitation | Journal of Clinical Medicine, v.14, no.12, pp 1 - 10 | - |
| dc.citation.title | Journal of Clinical Medicine | - |
| dc.citation.volume | 14 | - |
| dc.citation.number | 12 | - |
| dc.citation.startPage | 1 | - |
| dc.citation.endPage | 10 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | General & Internal Medicine | - |
| dc.relation.journalWebOfScienceCategory | Medicine, General & Internal | - |
| dc.subject.keywordPlus | INTRAOCULAR-PRESSURE | - |
| dc.subject.keywordPlus | SCLERAL TUNNEL | - |
| dc.subject.keywordPlus | ENDOPHTHALMITIS | - |
| dc.subject.keywordPlus | SURGERY | - |
| dc.subject.keywordPlus | PHACOEMULSIFICATION | - |
| dc.subject.keywordPlus | INTEGRITY | - |
| dc.subject.keywordPlus | OUTCOMES | - |
| dc.subject.keywordAuthor | clear corneal incisions | - |
| dc.subject.keywordAuthor | wound hydration | - |
| dc.subject.keywordAuthor | groove loss time | - |
| dc.identifier.url | https://www.mdpi.com/2077-0383/14/12/4091 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.