Groove Loss Time: A Novel Wound Leakage Test for Sutureless Clear Corneal Cataract Wound Incisionopen access

Authors
Hwang, SunjinKim, MoonsuYoon, JooyoungHong, Eun HeeShin, Yong UnKang, Min Ho
Issue Date
Jun-2025
Publisher
MDPI AG
Keywords
clear corneal incisions; wound hydration; groove loss time
Citation
Journal of Clinical Medicine, v.14, no.12, pp 1 - 10
Pages
10
Indexed
SCIE
SCOPUS
Journal Title
Journal of Clinical Medicine
Volume
14
Number
12
Start Page
1
End Page
10
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/208294
DOI
10.3390/jcm14124091
ISSN
2077-0383
2077-0383
Abstract
Background: This study introduces a novel quantitative method-groove loss time (GLT)-to objectively assess wound leakage following cataract surgery. Methods: In this prospective, single-center study, 70 eyes of 70 patients undergoing cataract surgery via CCI were enrolled. Wound sealing was evaluated by measuring the GLT, defined as the duration the stromal groove remains visible after corneal hydration. GLT was categorized into five grades: 'water-tight' (>10 s), 'excellent' (>5 s), 'good' (3-5 s), 'bad' (1-2 s), and 'poor' (<1 s). Intraocular pressure (IOP) was recorded at four time points: preoperatively, immediately post-surgery, 3-4 h postoperatively, and on postoperative day one. In select cases, anterior segment optical coherence tomography (AS-OCT) was used to confirm wound architecture. Results: All patients demonstrated a GLT longer than 5 s, corresponding to water-tight or excellent wound sealing. Mean IOP values were 16.08 +/- 3.61 mmHg preoperatively, 29.48 +/- 11.13 mmHg immediately post-surgery, 16.38 +/- 5.45 mmHg at 3-4 h, and 16.65 +/- 4.36 mmHg on the day after surgery. No cases of postoperative endophthalmitis, anterior chamber loss, or hypotony were observed. Conclusions: The GLT method provides a simple, objective, and effective tool for evaluating wound integrity in CCIs, ensuring optimal sealing and enhancing postoperative safety.
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 안과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Hong, Eun Hee photo

Hong, Eun Hee
서울 의과대학 (DEPARTMENT OF OPHTHALMOLOGY)
Read more

Altmetrics

Total Views & Downloads

BROWSE