Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Performance enhancement of steady-state visual evoked field-based brain–computer interfaces using spatial distribution of synchronization index in MEG channel spaceopen access

Authors
Kim, Ye-SungKim, Cheong-UnHan, HyojeongKim, Min-YoungChoi, Soo-InIm, Chang-Hwan
Issue Date
Sep-2025
Publisher
Academic Press
Keywords
Magnetoencephalography (MEG); Brain-computer interface (BCI); Steady-state visual evoked field (SSVEF); Calibration free algorithm
Citation
NeuroImage, v.318, pp 1 - 12
Pages
12
Indexed
SCIE
SCOPUS
Journal Title
NeuroImage
Volume
318
Start Page
1
End Page
12
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/210004
DOI
10.1016/j.neuroimage.2025.121391
ISSN
1053-8119
1095-9572
Abstract
The development of helmet-type magnetoencephalography (MEG) systems that do not require liquid helium (e.g., OPM-MEG) has sparked growing interest in steady-state visual evoked field (SSVEF)-based brain–computer interfaces (BCIs). Unlike electroencephalography (EEG), MEG records less distorted signals with a high spatial resolution, covering the entire head without requiring cumbersome electrode attachment. However, conventional algorithms, such as the filter bank-driven multivariate synchronization index (FBMSI), are prone to misclassification in ambiguous cases where the differences between synchronization indices (S indices) are minimal. Additionally, these algorithms fail to fully exploit high spatial resolution and whole-head coverage of MEG. To address these limitations, this study proposes a novel, calibration-free SSVEF classification algorithm termed Spatial Distribution Analysis (SDA). The SDA algorithm utilizes the center of gravity of the S index distribution in the MEG channel space to enhance classification accuracy. Experimental evaluations with 20 participants using a helmet-type SQUID MEG system demonstrated that the proposed SDA algorithm achieved significantly higher classification accuracy and information transfer rate (ITR) across all window sizes. Notably, the largest improvements of 5.76 % in accuracy and 4.87 bits/min in ITR were reported for a window size of 2.5 s. Furthermore, the generalizability of the SDA algorithm was validated on an OPM-MEG dataset, showing performance improvements across all window sizes. The SDA algorithm also mitigated misclassification due to adjacent stimuli and showed short time delay of 0.0907 s, enough to be used for real-time BCIs. These findings highlight the potential of SDA algorithm to enhance the overall performance of SSVEF-based BCI.
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > ETC > 1. Journal Articles
서울 공과대학 > 서울 융합전자공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Im, Chang Hwan photo

Im, Chang Hwan
COLLEGE OF ENGINEERING (서울 바이오메디컬공학전공)
Read more

Altmetrics

Total Views & Downloads

BROWSE