Suboptimal peak inspiratory flow rate in dry-powder inhaler users for chronic obstructive pulmonary disease in Koreaopen access

Authors
Moon, Ji-YongKim, Sang HyukKim, YoulimLee, HyunRhee, Chin KookRa, Seung WonLee, Chang YoulPark, Joo HunPark, Yong BumYoo, Kwang Ha
Issue Date
Jun-2024
Publisher
Academic Press
Keywords
Administration; Chronic pulmonary; Inhalation; Inhalation devices; Inspiratory capacity; Obstructive disease; Respiratory function tests
Citation
Pulmonary Pharmacology and Therapeutics, v.85, pp 1 - 6
Pages
6
Indexed
SCIE
SCOPUS
Journal Title
Pulmonary Pharmacology and Therapeutics
Volume
85
Start Page
1
End Page
6
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/211712
DOI
10.1016/j.pupt.2024.102298
ISSN
1094-5539
1522-9629
Abstract
Background: A suboptimal peak inspiratory flow rate (PIFR) in dry-powder inhaler (DPI) users can lead to insufficient therapeutic effects in the treatment of chronic obstructive pulmonary disease (COPD). However, few data on the prevalence of and factors associated with suboptimal PIFR in Korean patients with COPD are available. Methods: We conducted a cross-sectional study of patients with COPD who had been using DPIs for more than three months. PIFR was measured using an In-Check DIAL G16 device. Suboptimal PIFR was defined as below the resistance-matched threshold. Multivariable logistic regression analysis was used to determine factors associated with suboptimal PIFR. Results: Of 444 DPI users with COPD, the rate of suboptimal PIFR was 22.0 % (98/444). In a multivariable analysis, significant factors associated with suboptimal PIFR were age (adjusted odds ratio [aOR] = 1.06 by 1-year increase; 95 % confidence interval [CI] = 1.02–1.09), male sex (aOR = 0.28; 95 % CI = 0.11–0.73), body mass index (BMI) (aOR = 0.91 by 1 kg/m2 increase; 95 % CI = 0.85–0.99), post-bronchodilator forced vital capacity (FVC) %pred (aOR = 0.97 by 1%pred increase; 95 % CI = 0.95–0.99), and In-Check DIAL R2-type inhaler [medium-low resistance] use (aOR = 3.70 compared with R1-type inhalers [low resistance]; 95 % CI = 2.03–7.03). Conclusions: In Korea, more than one-fifth of DPI users with COPD had a suboptimal PIFR. The factors associated with suboptimal PIFR were age, female gender, low BMI, low FVC, and R2-type inhaler use. Therefore, clinicians should carefully evaluate the possibility of suboptimal PIFR when prescribing DPIs.
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 내과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Hyun photo

Lee, Hyun
서울 의과대학 (DEPARTMENT OF INTERNAL MEDICINE)
Read more

Altmetrics

Total Views & Downloads

BROWSE