Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Accuracy of Fully Automated and Human-assisted Artificia Intelligence–based CT Quantification of Pleural Effusion Changes after ThoracentesisAccuracy of Fully Automated and Human-assisted Artificial Intelligence-based CT Quantification of Pleural Effusion Changes after Thoracentesis

Other Titles
Accuracy of Fully Automated and Human-assisted Artificial Intelligence-based CT Quantification of Pleural Effusion Changes after Thoracentesis
Authors
Hwang, Eui JinHong, HyunsookKo, SeungyeonYoo, Seung-JinKim, HyungjinKim, DaheeYoon, Soon Ho
Issue Date
Jan-2025
Publisher
Radiological Society of North America
Citation
Radiology: Artificial Intelligence, v.7, no.1, pp 1 - 6
Pages
6
Indexed
SCOPUS
ESCI
Journal Title
Radiology: Artificial Intelligence
Volume
7
Number
1
Start Page
1
End Page
6
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/212366
DOI
10.1148/ryai.240215
ISSN
2638-6100
2638-6100
Abstract
Quantifying pleural effusion change at chest CT is important for evaluating disease severity and treatment response. The purpose of this study was to assess the accuracy of artificial intelligence (AI)–based volume quantification of pleural effusion change on CT images, using the volume of drained fluid as the reference standard. Seventy-nine participants (mean age ± SD, 65 years ± 13; 47 male) undergoing thoracentesis were prospectively enrolled from October 2021 to September 2023. Chest CT scans were obtained just before and after thoracentesis. The volume of pleural fluid on each CT scan, with the difference representing the drained fluid volume, was measured by automated segmentation (fully automated measurement). An expert thoracic radiologist then manually corrected these automated volume measurements (human-assisted measurement). Both fully automated (median percentage error, 13.1%; maximum estimated 95% error, 708 mL) and human-assisted measurements (median percentage error, 10.9%; maximum estimated 95% error, 312 mL) systematically underestimated the volume of drained fluid, beyond the equivalence margin. The magnitude of underestimation increased proportionally to the drainage volume. Agreements between fully automated and human-assisted measurements (intraclass correlation coefficient [ICC], 0.99) and the test-retest reliability of fully automated (ICC, 0.995) and human-assisted (ICC, 0.997) measurements were excellent. These results highlight a potential systematic discrepancy between AI segmentation–based CT quantification of pleural effusion volume change and actual volume change.
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 영상의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoo, Seung-Jin photo

Yoo, Seung-Jin
서울 의과대학 (DEPARTMENT OF RADIOLOGY)
Read more

Altmetrics

Total Views & Downloads

BROWSE