Boron-Doped Nano-Crystalline Coated Carbon Fibers for Phasic Dopamine Sensingopen access
- Authors
- Higham, Simon J.; Cabrera, Juan M. Rojas; Kwak, Youngjong; Hong, Lydia; Chambers, Andre; Nadarajah, Athavan; De Leon, Sorel E.; Jung, Young Jun; Jalilinejad, Negin; Blaha, Charles; Jang, Dong Pyo; Oh, Yoonbae; Lee, Kendall; Stacey, Alastair; Cloherty, Shaun L.; Ibbotson, Michael R.; Garrett, David J.; Prawer, Steven; Shin, Hojin; Tong, Wei
- Issue Date
- Apr-2026
- Publisher
- WILEY-V C H VERLAG GMBH
- Keywords
- carbon fiber; dopamine; fast-scan cyclic voltammetry; nano-crystalline; neurochemical sensing
- Citation
- ADVANCED HEALTHCARE MATERIALS, v.15, no.15, pp 1 - 19
- Pages
- 19
- Indexed
- SCIE
SCOPUS
- Journal Title
- ADVANCED HEALTHCARE MATERIALS
- Volume
- 15
- Number
- 15
- Start Page
- 1
- End Page
- 19
- URI
- https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/214332
- DOI
- 10.1002/adhm.202503945
- ISSN
- 2192-2640
2192-2659
- Abstract
- Real time, chronic electrochemical detection of neurotransmitters will provide a positive step in the treatment and understanding of neurological disease. However, current electrodes using carbon fibers (CF) fail to perform chronically. While diamond-based coatings show promise in improving their longevity, achieving a uniform layer of such coatings on CFs is challenging, and the electrodes often lose sensitivity after coating. In this work, a complete and uniform boron-doped nanocrystalline material grown in a diamond reactor (B-NCD) was developed to coat CF microelectrodes for neurochemical sensing. The coating was characterized electrically, optically, mechanically, and chemically. The B-NCD coated CF electrodes were able to detect phasic dopamine at a sensitivity comparable to the most widely used alternatives (uncoated and PEDOT:Nafion coated CFs). During biofouling testing, the B-NCD coated CF electrodes demonstrated better stability than uncoated CFs and comparable performance to PEDOT:Nafion coated CFs. Moreover, B-NCD exhibited no signs of degradation during consecutive FSCV applications, while uncoated and PEDOT:Nafion coated CF electrodes degraded significantly over time. Furthermore, the B-NCD coating supported the survival and development of neurons and astrocytes in vitro, exhibited excellent adhesion and durability during mechanical bending testing, and enabled successful in vivo recording of phasic dopamine release in the rat brain. Overall, B-NCD coated CFs present as an ideal candidate for chronic, flexible neural implantable electrodes for long-term neurochemical monitoring.
- Files in This Item
-
Go to Link
- Appears in
Collections - 서울 의생명공학전문대학원 > ETC > 1. Journal Articles

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.