Cited 0 time in
Dead-Time-Based Soft-Startup Strategy Enabling ZVS for DAB Converters in Railway Station Fast-Charging System
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kim, Jin-Chul | - |
| dc.contributor.author | Park, Chan-Bae | - |
| dc.contributor.author | Lee, Hyung-Woo | - |
| dc.contributor.author | Lee, Ju | - |
| dc.contributor.author | Lee, Jae-Bum | - |
| dc.date.accessioned | 2026-06-23T05:00:20Z | - |
| dc.date.available | 2026-06-23T05:00:20Z | - |
| dc.date.issued | 2026-05 | - |
| dc.identifier.issn | 1975-0102 | - |
| dc.identifier.issn | 2093-7423 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/214440 | - |
| dc.description.abstract | In railway-station fast-charging systems, Dual Active Bridge (DAB) converters are widely employed as DC/DC conversion stages and are typically operated in a multi-module configuration. During the initial start-up, it is essential to suppress excessive inrush current through an effective soft-start strategy. A soft-start method that adjusts dead time has been introduced to suppress inrush current while reducing the required number of PWM channels and simplifying the overall control structure. However, despite these advantages, this method inherently fails to achieve zero-voltage switching (ZVS) on the primary-side switches. To address this limitation, this paper proposes a novel dead-time-based soft-start strategy that enables ZVS operation while simultaneously mitigating inrush current. The proposed method prevents hard switching of the power devices from the initial stage of converter operation, thereby reducing device stress and switching losses. As a result, the overall reliability and lifetime of the fast-charging system are significantly improved. The effectiveness of the proposed strategy is validated through detailed simulations conducted on a 10 kW charging module operating with an input voltage of 800 V and an output voltage of 500 V. | - |
| dc.format.extent | 14 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | SPRINGER SINGAPORE PTE LTD | - |
| dc.title | Dead-Time-Based Soft-Startup Strategy Enabling ZVS for DAB Converters in Railway Station Fast-Charging System | - |
| dc.type | Article | - |
| dc.publisher.location | 싱가폴 | - |
| dc.identifier.doi | 10.1007/s42835-026-02611-4 | - |
| dc.identifier.scopusid | 2-s2.0-105028948922 | - |
| dc.identifier.wosid | 001676406100001 | - |
| dc.identifier.bibliographicCitation | JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, v.21, no.3, pp 3089 - 3102 | - |
| dc.citation.title | JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY | - |
| dc.citation.volume | 21 | - |
| dc.citation.number | 3 | - |
| dc.citation.startPage | 3089 | - |
| dc.citation.endPage | 3102 | - |
| dc.type.docType | Article in press | - |
| dc.identifier.kciid | ART003329020 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
| dc.subject.keywordPlus | DC-DC converters | - |
| dc.subject.keywordPlus | Electric drives | - |
| dc.subject.keywordPlus | Fast charging (Batteries) | - |
| dc.subject.keywordPlus | Railroad stations | - |
| dc.subject.keywordPlus | Railroads | - |
| dc.subject.keywordPlus | Zero current switching | - |
| dc.subject.keywordAuthor | Fast-charging system | - |
| dc.subject.keywordAuthor | Dual active bridge | - |
| dc.subject.keywordAuthor | Single-phase-shift | - |
| dc.subject.keywordAuthor | Inrush current | - |
| dc.subject.keywordAuthor | Zero voltage switching (ZVS) | - |
| dc.identifier.url | https://link.springer.com/article/10.1007/s42835-026-02611-4 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.