Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Oculomix: Hierarchical Sampling for Retinal-Based Systemic Disease Prediction

Authors
Kim, HyunminZhou, YukunJonas, Rahul A.Ju, LieHwang, SunjinKeane, Pearse A.Wagner, Siegfried K.
Issue Date
May-2026
Publisher
IEEE Computer Society
Keywords
CutMix; Data Augmentation; MixUp; Oculomics; Vision Transformer
Citation
Proceedings - International Symposium on Biomedical Imaging, pp 1 - 5
Pages
5
Indexed
SCOPUS
Journal Title
Proceedings - International Symposium on Biomedical Imaging
Start Page
1
End Page
5
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/218161
DOI
10.1109/ISBI61048.2026.11515349
ISSN
1945-7928
1945-8452
Abstract
Oculomics — the concept of predicting systemic diseases, such as cardiovascular disease and dementia, through retinal imaging — has advanced rapidly due to the data efficiency of transformer-based foundation models like RETFound. Image-level mixed sample data augmentations, such as CutMix and MixUp, are frequently used for training transformers, yet these techniques perturb patient-specific attributes, such as medical comorbidity and clinical factors, since they only account for images and labels. To address this limitation, we propose a hierarchical sampling strategy, Oculomix, for mixed sample augmentations. Our method is based on two clinical priors. First (exam level), images acquired from the same patient at the same time point share the same attributes. Second (patient level), images acquired from the same patient at different time points have a soft temporal trend, as morbidity generally increases over time. Guided by these priors, our method constrains the mixing space to the patient and exam levels to better preserve patient-specific characteristics and leverages their hierarchical relationships. The proposed method is validated using ViT models on a five-year prediction of major adverse cardiovascular events (MACE) in a large ethnically diverse population (Alzeye). We show that Oculomix consistently outperforms image-level CutMix and MixUp by up to 3% in AUROC, demonstrating the necessity and value of the proposed method in oculomics.
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 안과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Hwang, Sunjin photo

Hwang, Sunjin
서울 의과대학 (DEPARTMENT OF OPHTHALMOLOGY)
Read more

Altmetrics

Total Views & Downloads

BROWSE