An advanced technique for rapid and accurate monitoring of gaseous formaldehyde using large-volume injection interfaced with gas chromatograph/barrier discharge ionization detector (LVI/GC/BID)

Authors
Yoo, Mi-JiJo, Sang-HeeKim, Ki-Hyun
Issue Date
Jun-2019
Publisher
ELSEVIER SCIENCE BV
Keywords
Formaldehyde; Paraformaldehyde; Barrier discharge ionization detector; Large-volume injection system; Quantitative analysis
Citation
MICROCHEMICAL JOURNAL, v.147, pp 806 - 812
Pages
7
Indexed
SCI
SCIE
SCOPUS
Journal Title
MICROCHEMICAL JOURNAL
Volume
147
Start Page
806
End Page
812
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/2192
DOI
10.1016/j.microc.2019.03.096
ISSN
0026-265X
1095-9149
Abstract
As a hazardous volatile organic compound (VOC), formaldehyde (FA) is found ubiquitously in both polluted and unpolluted environments. Hence, for the proper control of FA, techniques for rapid and precise quantitation of FA are in great demand. However, because of its low molecular weight and high reactivity, its quantitation generally requires complicated procedures (such as combination of sampling through 2,4-dinitrophenylhydrazine (DNPH) derivatization and detection through high-performance liquid chromatograph (HPLC)). Such an approach, despite proven reliability, is inefficient for fast tracking of FA level under dynamic conditions. To overcome such limitations and to facilitate the near real-time monitoring of gaseous FA, we developed an alternative detection method based on a gas chromatograph/barrier discharge ionization detector interfaced with a large-volume injection system (LVI/GC/BID). The reliability of lab-made gaseous standards of formaldehyde was investigated based on thermal cracking of paraformaldehyde. The developed LVI/GC/BID approach allowed the detection of gaseous FA with a method detection limit (MDL) of about 0.13 ng (0.21 ppm for 0.5 mL sample) over the linear dynamic range of 0.29-5300 ng with relative standard deviation (RSD) of 1.19% compared with the direct injection-based GC/BID MDL of 2.41 ng (6.56 ppm for 0.3 mL sample) and RSD of 3.35%.
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 건설환경공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Ki Hyun photo

Kim, Ki Hyun
COLLEGE OF ENGINEERING (DEPARTMENT OF CIVIL AND ENVIRONMENTAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE