Development of skeletal system for mesh-type ICRP reference adult phantoms

Authors
Yeom, Yeon SooWang, Zhao JunThang Tat NguyenKim, Han SungChoi, ChansooHan, Min CheolKim, Chan HyeongLee, Jai KiChung, Beom SunZankl, MariaPetoussi-Henss, NinaBolch, Wesley E.Lee, Choonsik
Issue Date
Oct-2016
Publisher
IOP PUBLISHING LTD
Keywords
ICRP reference phantom; skeleton; voxel phantom; mesh phantom; Monte Carlo; dose coefficient
Citation
PHYSICS IN MEDICINE AND BIOLOGY, v.61, no.19, pp.7054 - 7073
Indexed
SCIE
SCOPUS
Journal Title
PHYSICS IN MEDICINE AND BIOLOGY
Volume
61
Number
19
Start Page
7054
End Page
7073
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/22149
DOI
10.1088/0031-9155/61/19/7054
ISSN
0031-9155
Abstract
The reference adult computational phantoms of the international commission on radiological protection (ICRP) described in Publication 110 are voxel-type computational phantoms based on whole-body computed tomography (CT) images of adult male and female patients. The voxel resolutions of these phantoms are in the order of a few millimeters and smaller tissues such as the eye lens, the skin, and the walls of some organs cannot be properly defined in the phantoms, resulting in limitations in dose coefficient calculations for weakly penetrating radiations. In order to address the limitations of the ICRP-110 phantoms, an ICRP Task Group has been recently formulated and the voxel phantoms are now being converted to a high-quality mesh format. As a part of the conversion project, in the present study, the skeleton models, one of the most important and complex organs of the body, were constructed. The constructed skeleton models were then tested by calculating red bone marrow (RBM) and endosteum dose coefficients (DCs) for broad parallel beams of photons and electrons and comparing the calculated values with those of the original ICRP-110 phantoms. The results show that for the photon exposures, there is a generally good agreement in the DCs between the mesh-type phantoms and the original voxel-type ICRP-110 phantoms; that is, the dose discrepancies were less than 7% in all cases except for the 0.03 MeV cases, for which the maximum difference was 14%. On the other hand, for the electron exposures (<= 4 MeV), the DCs of the mesh-type phantoms deviate from those of the ICRP-110 phantoms by up to similar to 1600 times at 0.03 MeV, which is indeed due to the improvement of the skeletal anatomy of the developed skeleton mesh models.
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE