Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

A Criticality Analysis of the GBC-32 Dry Storage Cask with Hanbit Nuclear Power Plant Unit 3 Fuel Assemblies from the Viewpoint of Burnup Creditopen access

Authors
Yun, HyungjuKim, Do-YeonPark, KwangheonHong, Ser Gi
Issue Date
Jun-2016
Publisher
한국원자력학회
Keywords
Axial Burnup Distribution; Burnup Credit; Dry Storage Cask; Monte Carlo N-Particle Transport Code, Version 6; Nuclear Criticality Safety Analysis; SCALE 6.1/STandardized Analysis of Reactivity for Burnup Credit using SCALE
Citation
Nuclear Engineering and Technology, v.48, no.3, pp.624 - 634
Indexed
SCIE
SCOPUS
KCI
Journal Title
Nuclear Engineering and Technology
Volume
48
Number
3
Start Page
624
End Page
634
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/22959
DOI
10.1016/j.net.2016.01.011
ISSN
1738-5733
Abstract
Nuclear criticality safety analyses (NCSAs) considering burnup credit were performed for the GBC-32 cask. The used nuclear fuel assemblies (UNFAs) discharged from Hanbit Nuclear Power Plant Unit 3 Cycle 6 were loaded into the cask. Their axial burnup distributions and average discharge burnups were evaluated using the DeCART and Multi-purpose Analyzer for Static and Transient Effects of Reactors (MASTER) codes, and NCSAs were performed using SCALE 6.1/STandardized Analysis of Reactivity for Burnup Credit using SCALE (STARBUCS) and Monte Carlo N-Particle transport code, version 6 (MCNP 6). The axial burnup distributions were determined for 20 UNFAs with various initial enrichments and burnups, which were applied to the criticality analysis for the cask system. The UNFAs for 20- and 30-year cooling times were assumed to be stored in the cask. The criticality analyses indicated that keff values for UNFAs with nonuniform axial burnup distributions were larger than those with a uniform distribution, that is, the end effects were positive but much smaller than those with the reference distribution. The axial burnup distributions for 20 UNFAs had shapes that were more symmetrical with a less steep gradient in the upper region than the reference ones of the United States Department of Energy. These differences in the axial burnup distributions resulted in a significant reduction in end effects compared with the reference.
Files in This Item
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Hong, Ser Gi photo

Hong, Ser Gi
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE