In vivo stiffness measurement and in silico stiffness prediction of biceps brachii muscle using an isometric contraction exercise
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Chung, Wan-Ho | - |
dc.contributor.author | Min, Dong-Ki | - |
dc.contributor.author | Hwang, Hyun-Jun | - |
dc.contributor.author | Lim, Jong-Kwang | - |
dc.contributor.author | Park, Jun-Hong | - |
dc.contributor.author | Kim, Hak-Sung | - |
dc.date.accessioned | 2021-07-30T04:58:53Z | - |
dc.date.available | 2021-07-30T04:58:53Z | - |
dc.date.created | 2021-05-12 | - |
dc.date.issued | 2016-06 | - |
dc.identifier.issn | 1738-494X | - |
dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/2552 | - |
dc.description.abstract | Cadavers are often used to measure the material properties of muscle via the static tensile loading test. However, the mechanical properties of the cadaver are different from that of in vivo muscle. In this work, a new way to measure the stiffness of in vivo muscle was proposed based on a vibration test combined with measured electromyography (EMG) signals. The stiffness of the biceps brachii muscle during isometric contractions with various weights (0 - 11 kg) was measured from the vibration test utilizing support properties of a spring attached to a mass. The relationship between the load level, the EMG signal, and the muscle stiffness was investigated and a multiple- spring model for biceps brachii muscle was newly suggested. Also, simulation using a commercial bio-mechanics simulation software (LifeMOD) was conducted to verify the developed muscle spring model and the measured stiffness of the in vivo muscle. The in vivo stiffness of the biceps brachii measured experimentally agreed well with the simulation result. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | KOREAN SOC MECHANICAL ENGINEERS | - |
dc.title | In vivo stiffness measurement and in silico stiffness prediction of biceps brachii muscle using an isometric contraction exercise | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Park, Jun-Hong | - |
dc.contributor.affiliatedAuthor | Kim, Hak-Sung | - |
dc.identifier.doi | 10.1007/s12206-016-0547-1 | - |
dc.identifier.scopusid | 2-s2.0-84975815557 | - |
dc.identifier.wosid | 000377935300047 | - |
dc.identifier.bibliographicCitation | JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, v.30, no.6, pp.2881 - 2889 | - |
dc.relation.isPartOf | JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY | - |
dc.citation.title | JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY | - |
dc.citation.volume | 30 | - |
dc.citation.number | 6 | - |
dc.citation.startPage | 2881 | - |
dc.citation.endPage | 2889 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.identifier.kciid | ART002112118 | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalWebOfScienceCategory | Engineering, Mechanical | - |
dc.subject.keywordPlus | TRICEPS SURAE | - |
dc.subject.keywordPlus | FIBER NUMBER | - |
dc.subject.keywordPlus | TENDON | - |
dc.subject.keywordPlus | FORCE | - |
dc.subject.keywordPlus | PARAMETERS | - |
dc.subject.keywordPlus | SIMULATION | - |
dc.subject.keywordPlus | PLACEMENT | - |
dc.subject.keywordPlus | MODELS | - |
dc.subject.keywordAuthor | In vivo muscle stiffness | - |
dc.subject.keywordAuthor | Isometric contraction | - |
dc.subject.keywordAuthor | Dynamics characteristic | - |
dc.subject.keywordAuthor | Hill-based muscle model | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1365
COPYRIGHT © 2021 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.