Detailed Information

Cited 1 time in webofscience Cited 2 time in scopus
Metadata Downloads

The selection of the standard phase (gas vs. liquid) and the related matrix effect on the direct injection gas chromatographic analysis of VOCs at sub-ppm levels

Authors
Iqbal, Mohammad AsifKim, Ki-HyunSzulejko, Jan E.Rahman, Md. Mahmudur
Issue Date
Jul-2014
Publisher
Elsevier BV
Keywords
Volatile organic compound (VOC); injection volume; sensitivity; fixed standard volume (FSV); calibration/response factor
Citation
Atmospheric Pollution Research, v.5, no.3, pp 563 - 571
Pages
9
Indexed
SCIE
SCOPUS
Journal Title
Atmospheric Pollution Research
Volume
5
Number
3
Start Page
563
End Page
571
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/25840
DOI
10.5094/APR.2014.065
ISSN
1309-1042
Abstract
In this study, the matrix effect on the quantitation of volatile organic compounds (VOCs) at sub–ppm levels has been investigated in relation to the selected standard phase by direct injection gas chromatographic (GC) analysis. To this end, a series of calibration experiments were conducted using both liquid and gas phase standards containing identically a total of 13 target VOCs. Calibration datasets between liquid and gas standards were obtained at the four selected injection volumes, i.e., covering a 1 to 5 and 50 to 500 μL range, respectively. The results indicate that injection volume is a sensitive parameter, as sensitivity tends to decrease with increasing injection volume, especially with liquid standards. Loss of analytes in liquid standard occurred noticeably from ones eluting earlier than solvent used for standard (i.e., methanol). If the extent of such loss is expressed by the percent differences in the response factor (RF) values between two standard types, the results were low or insignificant for valeraldehyde (0.48%), benzene (7.6%), toluene (3.3%), and styrene (4.8%) but generally high for the others (i.e., between 10–80%). The relative sensitivities of VOCs in gaseous standards, if computed by normalization against benzene, generally complied well with those derivable from the literature on flame ionization detectors. In contrast, in case of liquid standards, the use of a small injection volume (≤1 μL) is recommended to maintain the optimal GC performance in light of the matrix effect.
Files in This Item
There are no files associated with this item.
Appears in
Collections
서울 공과대학 > 서울 건설환경공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Ki Hyun photo

Kim, Ki Hyun
COLLEGE OF ENGINEERING (DEPARTMENT OF CIVIL AND ENVIRONMENTAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE