Contrasting recovery patterns of 2, 4-dinitrophenylhydrazones (DNPH) derivative of carbonyls between liquid and gas phase standards using HPLC-based analysis

Authors
Saha, Subbroto KumarJo, Sang-HeeSong, Hee-NamBrown, Richard J. C.Kim, Ki Hyun
Issue Date
Dec-2012
Publisher
PERGAMON-ELSEVIER SCIENCE LTD
Keywords
Carbonyl compound; DNPH cartridge; HPLC; Recovery; Standard-phase
Citation
ATMOSPHERIC ENVIRONMENT, v.62, pp.562 - 565
Indexed
SCIE
SCOPUS
Journal Title
ATMOSPHERIC ENVIRONMENT
Volume
62
Start Page
562
End Page
565
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/27413
DOI
10.1016/j.atmosenv.2012.09.005
ISSN
1352-2310
Abstract
This study evaluates the relative recovery (RR) of five different carbonyls (CCs) (i.e., acetaldehyde, propionaldehyde, butyraldehyde, isovaleraldehyde, and valeraldehyde) following their reaction as 2, 4-dinitrophenylhydrazine (DNPH) derivatives when using gas phase and liquid phase standards. To this end, relative efficiency of CC-DNPH derivatization is compared between two liquid-phase standards (commercially available vs. lab made mixture) and between liquid and gas-phase standard. If the results are compared in terms of response factors (RF) derived for five carbonyls from all different standard phases, the recovery of gaseous CC standard was distinguished from that of liquid counterparts. The RR of the heavier carbonyls (propionaldehyde, butyraldehyde, isovaleraldehyde, and valeraldehyde) was approximately 60% low relative to their liquid counterparts; however, it was not the case for the lighter carbonyls (acetaldehyde) with the RR of similar to 92%. This study thus suggests that the quantification of heavy carbonyls in ambient air, unless made by standards of the same matrix (i.e., gas phase) or compensated by the proper correction factor, may be subject to a large bias due to difference in derivatization reaction efficiency between matrix types. Hence, consideration of the matrix effect at the calibration stage is of particular importance to measure CC quantitatively. (c) 2012 Elsevier Ltd. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
서울 공과대학 > 서울 건설환경공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Ki Hyun photo

Kim, Ki Hyun
COLLEGE OF ENGINEERING (DEPARTMENT OF CIVIL AND ENVIRONMENTAL ENGINEERING)