Detailed Information

Cited 2 time in webofscience Cited 2 time in scopus
Metadata Downloads

Temporal resolution required for accurate evaluation of the interplay effect in spot scanning proton therapy

Authors
Seo, JeongminHan, Min CheolYeom, Yeon SooLee, Hyun SuKim, Chan HyeongJeong, Jong HwiKim, SeongHoon
Issue Date
Apr-2017
Publisher
한국물리학회
Keywords
Proton therapy; Spot scanning; Interplay effect; Temporal resolution
Citation
Journal of the Korean Physical Society, v.70, no.7, pp 720 - 725
Pages
6
Indexed
SCIE
SCOPUS
KCI
Journal Title
Journal of the Korean Physical Society
Volume
70
Number
7
Start Page
720
End Page
725
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/2762
DOI
10.3938/jkps.70.720
ISSN
0374-4884
1976-8524
Abstract
In proton therapy, the spot scanning method is known to suffer from the interplay effect induced from the independent movements of the proton beam and the organs in the patient during the treatment. To study the interplay effect, several investigators have performed four-dimensional (4D) dose calculations with some limited temporal resolutions (4 or 10 phases per respiratory cycle) by using the 4D computed tomography (CT) images of the patient; however, the validity of the limited temporal resolutions has not been confirmed. The aim of the present study is to determine whether the previous temporal resolutions (4 or 10 phases per respiratory cycle) are really high enough for adequate study of the interplay effect in spot scanning proton therapy. For this study, a series of 4D dose calculations were performed with a virtual water phantom moving in the vertical direction during dose delivery. The dose distributions were calculated for different temporal resolutions (4, 10, 25, 50, and 100 phases per respiratory cycle), and the calculated dose distributions were compared with the reference dose distribution, which was calculated using an almost continuously-moving water phantom (i.e., 1000 phases per respiratory cycle). The results of the present study show that the temporal resolutions of 4 and 10 phases per respiratory cycle are not high enough for an accurate evaluation of the interplay effect for spot scanning proton therapy. The temporal resolution should be at least 14 and 17 phases per respiratory cycle for 10-mm and 20-mm movement amplitudes, respectively, even for rigid movement (i.e., without deformation) of the homogeneous water phantom considered in the present study. We believe that even higher temporal resolutions are needed for an accurate evaluation of the interplay effect in the human body, in which the organs are inhomogeneous and deform during movement.
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics