Detailed Information

Cited 5 time in webofscience Cited 5 time in scopus
Metadata Downloads

An effective dose assessment technique with NORM added consumer products using skin-point source on computational human phantom

Authors
Yoo, Do HyeonShin, Wook-GeunLee, Hyun CheolChoi, Hyun JoonTesta, MauroLee, Jae KookYeom, Yeon SooKim, Chan HyeongMin, Chul Hee
Issue Date
Dec-2016
Publisher
PERGAMON-ELSEVIER SCIENCE LTD
Keywords
NORM; Consumer products; Effective dose; Monte Carlo simulation
Citation
APPLIED RADIATION AND ISOTOPES, v.118, pp.56 - 61
Indexed
SCIE
SCOPUS
Journal Title
APPLIED RADIATION AND ISOTOPES
Volume
118
Start Page
56
End Page
61
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/2790
DOI
10.1016/j.apradiso.2016.08.014
ISSN
0969-8043
Abstract
The aim of this study is to develop the assessment technique of the effective dose by calculating the organ equivalent dose with a Monte Carlo (MC) simulation and a computational human phantom for the naturally occurring radioactive material (NORM) added consumer products. In this study, we suggests the method determining the MC source term based on the skin-point source enabling the convenient and conservative modeling of the various type of the products. To validate the skin-point source method, the organ equivalent doses were compared with that by the product modeling source of the realistic shape for the pillow, waist supporter, sleeping mattress etc. Our results show that according to the source location, the organ equivalent doses were observed as the similar tendency for both source determining methods, however, it was observed that the annual effective dose with the skin-point source was conservative than that with the modeling source with the maximum 3.3 times higher dose. With the assumption of the gamma energy of 1 MeV and product activity of 1 Bq g(-1), the annual effective doses of the pillow, waist supporter and sleeping mattress with skin-point source was 3.09E-16 Sv Bq(-1) year(-1), 1.45E-15 Sv Bq(-1) year(-1), and 2,82E-16 Sv Bq(-1) year respectively, while the product modeling source showed 9.22E-17 Sv Bq(-1) year(-1), 9.29E-16 Sv Bq(-1) year(-1), and 8.83E-17 Sv Bq(-1) year(-1), respectively. In conclusion, it was demonstrated in this study that the skin -point source method could be employed to efficiently evaluate the annual effective dose due to the usage of the NORM added consumer products.
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE