Detailed Information

Cited 5 time in webofscience Cited 4 time in scopus
Metadata Downloads

Comparison of Accuracy of Left Atrial Area and Volume by Two-dimensional Trans-thoracic Echocardiography Versus Computed Tomography

Authors
Arsanjani, RezaFlint, NirBeigel, RoyKhachatryan, TigranShalev, AryehShturman, AlexanderLee, ChinRader, FlorianBerman, Daniel S.Heo, RanSiegel, Robert J
Issue Date
Apr-2019
Publisher
EXCERPTA MEDICA INC-ELSEVIER SCIENCE INC
Citation
AMERICAN JOURNAL OF CARDIOLOGY, v.123, no.7, pp.1180 - 1184
Indexed
SCIE
SCOPUS
Journal Title
AMERICAN JOURNAL OF CARDIOLOGY
Volume
123
Number
7
Start Page
1180
End Page
1184
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/3278
DOI
10.1016/j.amjcard.2018.12.047
ISSN
0002-9149
Abstract
Left atrial (LA) size is prognostic of cardiovascular events and can be quantified as diameter, area, or volume. While LA area measurement by 2-dimensional (2D) echocardiography is performed by tracing LA borders in the apical 4-chamber view, LA volume is derived from a formula that is based on geometrical assumptions. We compared LA area and volume measurements obtained by trans-thoracic echocardiography (TTE) to those obtained using multi-detector computed tomography (MDCT). Sixty-four patients with MDCT and TTE performed within a 1-week period were included in the study. End-systolic LA area was planimetered from the 4-chamber view by TTE and MDCT. LA end systolic volume was calculated using the biplane area-length (AL) method in both TTE and MDCT. Mean LA volume measurement using MDCT was significantly larger than TTE measurement (92 +/- 31 mL vs 68 +/- 27 mL, p<0.001). There was moderate correlation between MDCT and TTE in both LA area (0.74, p<0.0001), and volumetric measurements (0.77, p<0.0001). Bland-Altman agreement plots demonstrated a significantly lower bias and narrower 95% confidence intervals (CI) for the 2D area (bias: -5.5; 95% CI: -14.3 to 3.3) as compared with volumetric measurements (bias: -23.7; 95% CI: -64.9 to 17.5, p<0.0001). Contrary to current guidelines for chamber quantification, 2D TTE LA area has better agreement with MDCT than volumetric measurements by TTE. LA volumetric measurements are desirable; however, they are currently less reliable than the direct LA area tracing by 2D TTE and therefore represent a suboptimal and less reproducible method to determine LA size.
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 내과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Heo, Ran photo

Heo, Ran
COLLEGE OF MEDICINE (DEPARTMENT OF INTERNAL MEDICINE)
Read more

Altmetrics

Total Views & Downloads

BROWSE