Detailed Information

Cited 7 time in webofscience Cited 5 time in scopus
Metadata Downloads

Efficacy of 3D transoesophageal echocardiography for transcatheter device closure of atrial septal defect without balloon sizingopen access

Authors
Jang, J.Y.Heo, RanCho, M.S.Bae, J.Hong, J.A.Lee, S.Ahn, J.M.Park, D.W.Kim, D.H.Kang, D.H.Song, J.K.Song, J.M.
Issue Date
Jun-2018
Publisher
Oxford University Press
Keywords
atrial septal defect; 3D echocardiography; transcatheter intervention
Citation
European Heart Journal Cardiovascular Imaging, v.19, no.6, pp.684 - 689
Indexed
SCIE
SCOPUS
Journal Title
European Heart Journal Cardiovascular Imaging
Volume
19
Number
6
Start Page
684
End Page
689
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/3339
DOI
10.1093/ehjci/jex153
ISSN
2047-2404
Abstract
Aims Using balloon sizing to determine device size may cause complications and increase procedure time in performing transcatheter closure of atrial septal defect (ASD). We aimed to validate the clinical utility of a formula using measurements from 3D transoesophageal echocardiography (TOE) images in performing the procedure without balloon sizing. Methods and results We enrolled 248 consecutive patients with ASD in a prospective registry. In the first tier (n = 53), we determined the device size before the procedure using our formula and performed balloon sizing during the procedure to verify our decision. In the second tier (n = 195), the procedure was performed without balloon sizing. In the first tier, the estimated device size correlated well with the device size finally implanted (R = 0.961, P < 0.001; bias, 0.38 ± 1.5 mm, P < 0.001) and with the stretched balloon diameter (R = 0.929, P < 0.001; bias, 0.13 ± 2.0 mm, P < 0.001). In the second tier, the device size derived from the formula was used in all patients, with the exception of one patient who showed a deficient rim on the aorta and superior sides and ASD that was not on a single plane. Two patients with unfavourable morphologies for device implantation experienced embolization of the device. Of the 193 patients with procedural success (99.0%), 2 suffered from haemopericardium caused by atrial wall erosion by the device. There were no procedure-related deaths. Conclusion The transcatheter closure of ASD using the 3D TOE-derived formula without balloon sizing is clinically feasible and safe. However, caution should be taken to exclude unfavourable features of ASD (ClinicalTrials.gov number NCT 02097758).
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 내과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Heo, Ran photo

Heo, Ran
COLLEGE OF MEDICINE (DEPARTMENT OF INTERNAL MEDICINE)
Read more

Altmetrics

Total Views & Downloads

BROWSE