The applicability of a large-volume injection (LVI) system for quantitative analysis of permanent gases O-2 and N-2 using a gas chromatograph/barrier discharge ionization detector

Authors
Jo, Sang-HeeKim, Ki-Hyun
Issue Date
Jul-2017
Publisher
Springer Nature
Keywords
Permanent gas; Barrier discharge ionization detector; Large-volume injection system; Calibration; Polyester aluminum bag
Citation
Environmental Monitoring and Assessment, v.189, no.7, pp 1 - 10
Pages
10
Indexed
SCIE
SCOPUS
Journal Title
Environmental Monitoring and Assessment
Volume
189
Number
7
Start Page
1
End Page
10
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/4133
DOI
10.1007/s10661-017-6024-1
ISSN
0167-6369
1573-2959
Abstract
To develop accurate quantitation methods for two major permanent gases, N-2 and O-2, a series of calibration experiments were carried out using a gas chromatograph (GC)/barrier discharge ionization detector (BID) equipped with a large-volume injection (LVI) system. To this end, gaseous working standards (WSs) diluted with helium gas were prepared at ten different concentration levels representing three different concentration ranges (in ppm) in 1-L polyester aluminum (PEA) bags ((1) low, 209 similar to 2090 (O-2) and 791 similar to 7910 (N-2); (2) moderate, 2090 similar to 20,900 (O-2) and 7910 similar to 79,100 (N-2); and (3) high, 20,900 similar to 209,000 (O-2) and 79,100 similar to 791,000 (N-2)). Cross-calibration experiments for each individual WS were carried out using the loop injection system with four different capacities (0.01, 0.5, 1, and 10 mL). The calibration results were then evaluatedwith respect to key variables including loop capacity, concentration, and mass quantity. Accordingly, we observed the optimal performance of the BID in terms of sensitivity and linearity (R-2 > 0.98) when the WS of the moderate concentration range was analyzed with the small loop (0.01 and 0.5 mL). The method detection limit (MDL) values of the four loop sizes (between 0.01 and 10 mL) were 7 similar to 500 ng for O-2 (38.4 similar to 557 ppm) and 24 similar to 2230 ng for N-2 (195 similar to 2105 ppm).
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 건설환경공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Ki Hyun photo

Kim, Ki Hyun
COLLEGE OF ENGINEERING (DEPARTMENT OF CIVIL AND ENVIRONMENTAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE