Detailed Information

Cited 8 time in webofscience Cited 8 time in scopus
Metadata Downloads

2-dimensional shear wave elastography: Interobserver agreement and factors related to interobserver discrepancyopen access

Authors
Yoon, KiboJeong, Woo KyoungKim, YongsooKim, Min YeongKim, Tae YeobSohn, Joo Hyun
Issue Date
Apr-2017
Publisher
PUBLIC LIBRARY SCIENCE
Citation
PLOS ONE, v.12, no.4
Indexed
SCIE
SCOPUS
Journal Title
PLOS ONE
Volume
12
Number
4
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/4259
DOI
10.1371/journal.pone.0175747
ISSN
1932-6203
Abstract
Purpose To evaluate the interobserver reproducibility of two-dimensional shear wave elastography (2D-SWE) in measuring liver stiffness (LS) and to investigate factors related to liver 2D-SWE. Materials and methods A prospective study was conducted between August 2011 and August 2012 in rheumatoid arthritis patients who had been treated with methotrexate. Interobserver reproducibility of 2D-SWE was evaluated, and the relationship between interobserver difference in LS and related factors was analyzed using linear regression analyses. We considered age, sex, alanine transaminase, cholesterol, body mass index (BMI), and waist circumference as clinical factors, and the mean value of standard deviation (SDM), its difference between two examiners, mean diameter of the regions of interest (ROIM), and its difference in the elasticity map as investigation factors. The cut-off value for significant factors to predict interobserver discrepancies in LS-based fibrosis stage was also inspected. Results In total, 176 patients were enrolled. The intraclass correlation coefficient between the two examiners was 0.784. In the univariate analysis, SDM and ROIM were independently associated with interobserver differences in LS as well as BMI, waist circumference, and the difference of ROI, but SDM and ROIM were the only ones significantly related in multivariate analysis (p<0.001 and p = 0.021, respectively). The best cut-off value for SDM in predicting interobserver discrepancy in LS-based fibrosis stage was 1.4. Conclusions Interobserver reproducibility of 2D-SWE for measuring LS was good and SDM was the most significantly associated factor with interobserver differences in LS and interobserver discordance in LS-based fibrosis stage.
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 내과학교실 > 1. Journal Articles
서울 의과대학 > 서울 영상의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Yong Soo photo

Kim, Yong Soo
COLLEGE OF MEDICINE (DEPARTMENT OF RADIOLOGY)
Read more

Altmetrics

Total Views & Downloads

BROWSE