Dose rate measurement of Leksell Gamma Knife Perfexion using a 3D printed plastic scintillation dosimeter
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Sangmin | - |
dc.contributor.author | Kim, Tae Hoon | - |
dc.contributor.author | Jeong, Jae Young | - |
dc.contributor.author | Son, Jaebum | - |
dc.contributor.author | Kim, Dong Geon | - |
dc.contributor.author | Cho, Gyu-Seok | - |
dc.contributor.author | Choi, Sang Hyoun | - |
dc.contributor.author | Chung, Hyun-Tai | - |
dc.contributor.author | Kim, Yong Kyun | - |
dc.date.accessioned | 2021-08-02T08:51:43Z | - |
dc.date.available | 2021-08-02T08:51:43Z | - |
dc.date.created | 2021-05-12 | - |
dc.date.issued | 2020-10 | - |
dc.identifier.issn | 1738-5733 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/8879 | - |
dc.description.abstract | In recent years, 3D printing technology has received significant research attention. Additionally, 3D printing technology is being applied to study radiation dosimeters of various materials. In this study, a plastic scintillator for 3D printing was developed in a laboratory and used to manufacture a plastic scintillation dosimeter (PSD) with a shape identical to that of the ionization chamber PTW31010. The 16-mm beam of Gamma Knife (R) Perfexion (TM) was irradiated to derive the absorbed dose rates of the PSD and PTW31010; they were subsequently compared with the dose rates of the treatment plan. The differences in the dose rates of the Gamma Knife treatment plan and the absorbed dose rates of PTW31010 were within 0.87%. The difference between the dose rates of the Gamma Knife treatment plan and the absorbed dose rates of the PSD were within 4.1%. A linear fit of the absorbed dose rates of four shots involving different dose rates and irradiation angles yielded an adjusted R-square value exceeding 0.9999. A total of 10 repeated measurements were conducted for the same shot to confirm its reproducibility, with a relative error of 0.56%. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | KOREAN NUCLEAR SOC | - |
dc.title | Dose rate measurement of Leksell Gamma Knife Perfexion using a 3D printed plastic scintillation dosimeter | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kim, Yong Kyun | - |
dc.identifier.doi | 10.1016/j.net.2020.03.021 | - |
dc.identifier.scopusid | 2-s2.0-85082741496 | - |
dc.identifier.wosid | 000560711000008 | - |
dc.identifier.bibliographicCitation | NUCLEAR ENGINEERING AND TECHNOLOGY, v.52, no.10, pp.2334 - 2338 | - |
dc.relation.isPartOf | NUCLEAR ENGINEERING AND TECHNOLOGY | - |
dc.citation.title | NUCLEAR ENGINEERING AND TECHNOLOGY | - |
dc.citation.volume | 52 | - |
dc.citation.number | 10 | - |
dc.citation.startPage | 2334 | - |
dc.citation.endPage | 2338 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.identifier.kciid | ART002634935 | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | Y | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
dc.relation.journalResearchArea | Nuclear Science & Technology | - |
dc.relation.journalWebOfScienceCategory | Nuclear Science & Technology | - |
dc.subject.keywordPlus | VERIFICATION | - |
dc.subject.keywordAuthor | Plastic scintillator | - |
dc.subject.keywordAuthor | 3D printing | - |
dc.subject.keywordAuthor | Gamma Knife | - |
dc.subject.keywordAuthor | Dosimeter | - |
dc.subject.keywordAuthor | Treatment plan | - |
dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S1738573320300681?via%3Dihub | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1365
COPYRIGHT © 2021 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.