Detailed Information

Cited 5 time in webofscience Cited 3 time in scopus
Metadata Downloads

Validation of noncontact cardiorespiratory monitoring using impulse-radio ultra-wideband radar against nocturnal polysomnography

Authors
Kang, SunLee, YongguLim, Young-HyoPark, Hyun-KyungCho, Sung HoCho, Seok Hyun
Issue Date
Sep-2020
Publisher
SPRINGER HEIDELBERG
Keywords
Cardiopulmonary; Apnea; Radar; Polysomnography; Noncontact; Monitoring
Citation
SLEEP AND BREATHING, v.24, no.3, pp.841 - 848
Indexed
SCIE
SCOPUS
Journal Title
SLEEP AND BREATHING
Volume
24
Number
3
Start Page
841
End Page
848
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/8935
DOI
10.1007/s11325-019-01908-1
ISSN
1520-9512
Abstract
Purpose Polysomnography (PSG) is a standard diagnostic test for obstructive sleep apnea (OSA). However, PSG requires many skin-contacted sensors to monitor vital signs of patients, which may also hamper patients’ sleep. Because impulse-radio ultra-wideband (IR-UWB) radar can detect the movements of heart and lungs without contact, it may be utilized for vital sign monitoring during sleep. Therefore, we aimed to verify the accuracy and reliability of the breathing rate (BR) and the heart rate (HR) measured by IR-UWB radar. Method Data acquisition with PSG and IR-UWB radar was performed simultaneously in 6 healthy volunteers and in 15 patients with suspected OSA. Subjects were divided into 4 groups (normal, mild OSA, moderate OSA, and severe OSA) according to the apnea-hypopnea index (AHI). BRs and HRs obtained from the radar using a software algorithm were compared with the BRs (chest belt) and the HRs (electrocardiography) obtained from the PSG. Results In normal and in mild OSA, BRs (intraclass correlation coefficients R [ICCR] 0.959 [0.956–0.961] and 0.957 [0.955–0.960], respectively) and HRs ([ICCR] 0.927 [0.922–0.931] and 0.926 [0.922–0.931], respectively) measured in the radar showed excellent agreement with those measured in PSG. In moderate and severe OSA, BRs ([ICCR] 0.957 [0.956–0.959] and 0.873 [0.864–0.882], respectively) and HRs ([ICCR] 0.907 [0.904–0.910] and 0.799 [0.784–0.812], respectively) from the two methods also agreed well. Conclusions The IR-UWB radar could accurately measure BRs and HRs in sleeping patients with OSA. Therefore, IR-UWB radar may be utilized as a cardiopulmonary monitor during sleep.
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 융합전자공학부 > 1. Journal Articles
서울 의과대학 > 서울 소아청소년과학교실 > 1. Journal Articles
서울 의과대학 > 서울 내과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Yong gu photo

Lee, Yong gu
COLLEGE OF MEDICINE (DEPARTMENT OF INTERNAL MEDICINE)
Read more

Altmetrics

Total Views & Downloads

BROWSE