Detailed Information

Cited 2 time in webofscience Cited 2 time in scopus
Metadata Downloads

Body-size-dependent phantom library constructed from ICRP mesh-type reference computational phantoms

Authors
Choi, ChansooYeom, Yeon SooLee, HanjinHan, HaeginShin, BanghoThang Tat NguyenKim, Chan Hyeong
Issue Date
Jun-2020
Publisher
IOP PUBLISHING LTD
Keywords
ICRP reference phantom; non-reference phantom; mesh phantom; phantom library; body size; Monte Carlo simulation; individual dose reconstruction
Citation
PHYSICS IN MEDICINE AND BIOLOGY, v.65, no.12, pp.1 - 15
Indexed
SCIE
SCOPUS
Journal Title
PHYSICS IN MEDICINE AND BIOLOGY
Volume
65
Number
12
Start Page
1
End Page
15
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/9804
DOI
10.1088/1361-6560/ab8ddc
ISSN
0031-9155
Abstract
Recently, ICRP Task Group 103 developed new mesh-type reference computational phantoms (MRCPs) for the adult male and female by converting the current voxel-type reference computational phantoms (VRCPs) of ICRPPublication 110into a high-quality/fidelity mesh format. Utilizing the great deformability/flexibility of the MRCPs compared with the VRCPs, in the present study, we established a body-size-dependent phantom library by modifying the MRCPs. The established library includes 108 adult male and 104 adult female phantoms in different standing heights and body weights, covering most body sizes representative of Caucasian and Asian populations. Ten secondary anthropometric parameters with respect to standing height and body weight were derived from various anthropometric databases and applied in the construction of the phantom library. An in-house program for automatic phantom adjustment was developed and applied for practical construction of such a large number of phantoms in the library with minimized human intervention. Organ/tissue doses calculated with three male phantoms in different standing heights (165, 175, and 190 cm) with a fixed body weight of 80 kg for external exposures to broad parallel photon beams from 0.01 to 10(4)MeV were compared, observing there are significant dose differences particularly for the photon energies <0.1 MeV in which the organ/tissue doses tended to increase with increasing standing height. In addition, the organ/tissue doses of three female phantoms in different body weights (45, 65, and 140 kg) with a fixed standing height of 165 cm were compared, showing a significant decreasing tendency with increasing body weight for the photon energies <10 MeV. For the higher energies, the opposite trend, interestingly, was observed; that is, the organ/tissue doses tended to increase with increasing body weight. The results, despite the limited number of exposure cases, suggest that the use of the body-size-dependent phantom library can improve the accuracy of individual dose estimates for many retrospective dosimetry studies by taking the body size of individuals into account.
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE