전자식 점화안전장치 회로 시스템 내부 소자 변화에 따른 민감 소자 확인 및 출력 특성에 대한 신뢰성 분석 프로세스Identifying Sensitive Components and Analyzing Reliability Process to Output Characteristic for an EAFD Circuit System According to Changes of Internal Component Values

Other Titles
Identifying Sensitive Components and Analyzing Reliability Process to Output Characteristic for an EAFD Circuit System According to Changes of Internal Component Values
Authors
임태흥변강일장승교백승준손영갑추호성
Issue Date
2018
Publisher
한국군사과학기술학회
Keywords
EAFD(전자식 점화안전장치); Reliability Analysis of Circuit System(회로 시스템의 신뢰성분석); Ouput Characteristics of the EAFD Circuit(EAFD 회로 출력 특성); Analysis of Sensitive Components(민감 소자분석)
Citation
한국군사과학기술학회지, v.21, no.5, pp.697 - 703
Journal Title
한국군사과학기술학회지
Volume
21
Number
5
Start Page
697
End Page
703
URI
https://scholarworks.bwise.kr/hongik/handle/2020.sw.hongik/13097
DOI
10.9766/KIMST.2018.21.5.697
ISSN
1598-9127
Abstract
In this paper, we analyzed the operation of the ignition circuit for electronic arm and fire device(EAFD), and investigated the sensitive elements of the circuit system. For reliability analysis, the EAFD ignition circuit was modeled using the PSpice simulation tool, and the output results of the circuit were examined by changing the tolerance of each circuit element. Monte Carlo simulation was used by maintaining the values of the observed sensitive elements at ±10 % of the original values and adjusting the values of the other components according to a random distribution. The histogram results of the output peak currents and pulse widths were represented by Weibull and Burr type XII function fittings in three cases(element values are +10 %, 0 %, -10 % of original). For the output peak currents, mean values were 1.0028, 1.0034, and 1.0050, where the variance values were calculated as 0.0398, 0.0396, and 0.0290 using the Weibull function fitting, respectively. For pulse widths, the mean values of 0.9475, 0.9907, and 1.0293 with the variance values of 0.0260, 0.0251, and 0.0238 were obtained using the Burr Type XII function fittings.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Electronic & Electrical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choo, Ho sung photo

Choo, Ho sung
Engineering (Electronic & Electrical Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE