Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Tunnel lighting control system using fuzzy reasoning

Authors
Lee, J.-E.Choi, H.-K.
Issue Date
2014
Publisher
Korean Institute of Electrical Engineers
Keywords
Fuzzy logic control system; Threshold zone; Tunnel light
Citation
Transactions of the Korean Institute of Electrical Engineers, v.63, no.8, pp.1140 - 1145
Journal Title
Transactions of the Korean Institute of Electrical Engineers
Volume
63
Number
8
Start Page
1140
End Page
1145
URI
https://scholarworks.bwise.kr/hongik/handle/2020.sw.hongik/16454
DOI
10.5370/KIEE.2014.63.8.1140
ISSN
1975-8359
Abstract
Tunnel lighting is composed of entrance zone, interior zone and exit zone by KS C 3703. We have to consider adaptation at entrance zone and exit zone lighting to prevent deteriorate visibility like black hole and white hole phenomenon. So External luminance, vehicle velocity and traffic volume should be considered in threshold zone lighting and vehicle speed and traffic volume should be considered in interior zone lighting. But existing tunnel lighting system is not good at visibility and economic because that is only contraled by external luminance. So in this paper, We improve visibility and economic of tunnel lighting system using fuzzy reasoning according to external luminance, vehicle velocity, traffic volume.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Science and Technology > Department of Electronic and Electrical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE