Perforated FRP shear connector for the FRP-concrete composite bridge deck

Authors
Nam, J.-H.Yoon, S.-J.Ok, D.-M.Cho, S.-K.
Issue Date
2007
Publisher
Trans Tech Publications Ltd
Keywords
FRP-concrete composite bridge deck; Perforated FRP shear connector; Push-out test; Shear behavior
Citation
Key Engineering Materials, v.334-335 I, pp.381 - 384
Journal Title
Key Engineering Materials
Volume
334-335 I
Start Page
381
End Page
384
URI
https://scholarworks.bwise.kr/hongik/handle/2020.sw.hongik/24174
DOI
10.4028/0-87849-427-8.381
ISSN
1013-9826
Abstract
In recent years, the FRP-concrete composite bridge deck system has been introduced because of its light-weight and durability. The FRP-concrete composite bridge deck is composed of FRP module and concrete, and they are connected with shear connectors. In order to insure the composite action between FRP module and concrete, appropriate types of shear connector need to be installed. In this study, new type of FRP shear connector was suggested and the experimental investigations are conducted based on the studies of Perfobond. In the experimental study, the push-out test was conducted and the load carrying mechanism was analyzed including the friction effect of sand coating. Considering the load carrying mechanism of perforated shear connector under shear force, the empirical equation for the prediction of shear strength of perforated FRP shear connector was suggested.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Civil Engineering Major > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE