Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

교류방식 유속 측정법 개발Development of AC Thermal Anemometry

Other Titles
Development of AC Thermal Anemometry
Authors
권오명이준식최두선최영기정원석박승호
Issue Date
2004
Publisher
대한기계학회
Keywords
Phase Lag(위상 뒤짐); Alternating Current(교류); Hotwire(열선)
Citation
대한기계학회논문집 B, v.28, no.2, pp.230 - 237
Journal Title
대한기계학회논문집 B
Volume
28
Number
2
Start Page
230
End Page
237
URI
https://scholarworks.bwise.kr/hongik/handle/2020.sw.hongik/26436
ISSN
1226-4881
Abstract
This paper suggests and demonstrates a novel flow measurement technique: tunable AC thermal anemometry that allows simple integration, robust measurement, and extremely high accuracy. The principle and simple theoretical analysis of the technique are presented. To find the optimal condition at which the phase lag becomes most sensitive to flow speed change, the phase lag was measured scanning the heating frequency from 1 to 100 Hz, while the flow speed of ethanol was increased stepwise from 0 to 40 mm/s. The sensitivity of phase lag depended on the heating frequency and the flow speed. It was possible to measure the flow speed of 0.7 mm/s with the resolution of 0.1 mm/s at 4 Hz.