Two-dimensional model for tapered pulse tubes. Part 2: mass streaming and streaming-driven enthalpy flow loss

Authors
Baek, SHJeong, ESJeong, S
Issue Date
Jun-2000
Publisher
ELSEVIER SCI LTD
Keywords
pulse tube refrigerators; tapered pulse tubes; two-dimensional model; mass streaming; streaming-driven enthalpy flow loss
Citation
CRYOGENICS, v.40, no.6, pp.387 - 392
Journal Title
CRYOGENICS
Volume
40
Number
6
Start Page
387
End Page
392
URI
https://scholarworks.bwise.kr/hongik/handle/2020.sw.hongik/27357
DOI
10.1016/S0011-2275(00)00058-8
ISSN
0011-2275
Abstract
The effects of the taper angle and the frequency on the steady mass flux and the enthalpy flow loss associated with the steady mass streaming were analyzed by two-dimensional analysis of the tapered pulse tube. It was shown that the mass streaming could lead to a large steady second-order temperature, The enthalpy flow loss driven by the mass streaming increases as the frequency increases. For the pulse tube where the viscous penetration depth is far thinner than the inner radius, the enthalpy flow loss can be significantly reduced by tapering the pulse tube since the steady mass flux and the steady second-order temperature decrease as the taper angle increases. (C) 2001 Elsevier Science Ltd. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Mechanical and System Design Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE