Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

P2G 기반 마이크로그리드의 경제성 분석 및 보급 방안에 관한 연구A Study on the Economic Analysis and the Diffusion Strategy of P2G-based Microgrid

Other Titles
A Study on the Economic Analysis and the Diffusion Strategy of P2G-based Microgrid
Authors
황성욱이학주김정훈
Issue Date
2021
Publisher
대한전기학회
Keywords
Bass Diffusion Model; Economic Analysis; Excess Energy; HOMER; Hydrogen Economy; Net Present Cost; Power-to-Gas; P2G-based Microgrid; Renewable Energy; Subsidy Level
Citation
전기학회논문지, v.70, no.2, pp.305 - 313
Journal Title
전기학회논문지
Volume
70
Number
2
Start Page
305
End Page
313
URI
https://scholarworks.bwise.kr/hongik/handle/2020.sw.hongik/29525
ISSN
1975-8359
Abstract
Recently, global interest in the hydrogen economy is increasing, and most advanced countries, as well as Korea, have established and implemented various policies to foster the hydrogen industry. Hydrogen is considered as an energy carrier that is able to integrate and control existing energy such as electricity, gas, and heat in one dimension, and theoretically, its possibility has already been confirmed. As the first step to implement this, advanced countries such as Switzerland and Germany are leading the development of Powr-to-Gas (P2G) technology. In Korea, some energy-related organizations are conducting various researches recently, and KEPCO (Korea Electric Power Corporation) began research to connect the P2G-based microgrid to the distribution grid in 2019. Currently, the design and construction of the demonstration site is in progress. In this paper, the economic feasibility of a P2G-based microgrid is analyzed and an appropriate direction of penetration is proposed considering the increase of hydrogen load. For the economic analysis, HOMER Pro, which is widely used worldwide for evaluating the economics of renewable energy and microgrids, is used and Bass' diffusion model is applied to predict the increase of hydrogen load. In the case study, the economic analysis is carried out to derive the optimal facility configuration for 10% of the total load of the Ulsan techno-industrial complex under construction of the P2G-based microgrid demonstration site. As well as the sensitivity according to the level of hydrogen load is evaluated for the purpose of utilization of unused energy caused by renewable energy.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Electronic & Electrical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE