Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

JUST-Net: Jointly unrolled cross-domain optimization based spatio-temporal reconstruction network for accelerated 3D myelin water imagingopen access

Authors
Lee, Jae-HunKim, Jae-YoonRyu, KanghyunAl-masni, Mohammed A.Kim, Tae HyungHan, DongyeobKim, Hyun GiKim, Dong-Hyun
Issue Date
Jun-2024
Publisher
John Wiley and Sons Inc
Keywords
accelerating 3D multi-echo gradient-echo; deep learning; myelin water imaging; prospectively accelerated acquisition; reproducibility test; spatio-temporal reconstruction
Citation
Magnetic Resonance in Medicine, v.91, no.6, pp 2483 - 2497
Pages
15
Journal Title
Magnetic Resonance in Medicine
Volume
91
Number
6
Start Page
2483
End Page
2497
URI
https://scholarworks.bwise.kr/hongik/handle/2020.sw.hongik/32738
DOI
10.1002/mrm.30021
ISSN
0740-3194
1522-2594
Abstract
Purpose: We introduced a novel reconstruction network, jointly unrolled cross-domain optimization-based spatio-temporal reconstruction network (JUST-Net), aimed at accelerating 3D multi-echo gradient-echo (mGRE) data acquisition and improving the quality of resulting myelin water imaging (MWI) maps. Method: An unrolled cross-domain spatio-temporal reconstruction network was designed. The main idea is to combine frequency and spatio-temporal image feature representations and to sequentially implement convolution layers in both domains. The k-space subnetwork utilizes shared information from adjacent frames, whereas the image subnetwork applies separate convolutions in both spatial and temporal dimensions. The proposed reconstruction network was evaluated for both retrospectively and prospectively accelerated acquisition. Furthermore, it was assessed in simulation studies and real-world cases with k-space corruptions to evaluate its potential for motion artifact reduction. Results: The proposed JUST-Net enabled highly reproducible and accelerated 3D mGRE acquisition for whole-brain MWI, reducing the acquisition time from fully sampled 15:23 to 2:22 min within a 3-min reconstruction time. The normalized root mean squared error of the reconstructed mGRE images increased by less than 4.0%, and the correlation coefficients for MWI showed a value of over 0.68 when compared to the fully sampled reference. Additionally, the proposed method demonstrated a mitigating effect on both simulated and clinical motion-corrupted cases. Conclusion: The proposed JUST-Net has demonstrated the capability to achieve high acceleration factors for 3D mGRE-based MWI, which is expected to facilitate widespread clinical applications of MWI. © 2024 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine.
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Tae Hyung photo

Kim, Tae Hyung
Engineering (Department of Computer Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE