Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Synergetic effects of Mo2C sphere/SCN nanocatalysts interface for nanomolar detection of uric acid and folic acid in presence of interferencesopen access

Authors
Ganesh, Pattan-SiddappaGovindasamy, ManiKim, Sang-YounChoi, Dong-SooKo, Hyun-U.Alshgari, Razan AbdullahHuang, Chi-Hsien
Issue Date
Mar-2023
Publisher
ACADEMIC PRESS INC ELSEVIER SCIENCE
Keywords
Electrochemical sensing; Transition metal carbides; Electrocatalyst; Nanosensor; Real samples
Citation
ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, v.253
Journal Title
ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY
Volume
253
URI
https://scholarworks.bwise.kr/kumoh/handle/2020.sw.kumoh/21637
DOI
10.1016/j.ecoenv.2023.114694
ISSN
0147-6513
1090-2414
Abstract
Till to date, the application of sulfur-doped graphitic carbon nitride supported transition metal carbide interface for electrochemical sensor fabrication was less explored. In this work, we designed a simple synthesis of mo-lybdenum carbide sphere embedded sulfur doped graphitic carbon nitride (Mo2C/SCN) catalyst for the nano -molar electrochemical sensor application. The synthesized Mo2C/SCN nanocatalyst was systematically characterized using X-ray diffraction (XRD) and scanning electron microscopy (SEM) with elemental mapping. The SEM images show that the porous SCN network adhered uniformly on Mo2C, causing a loss of crystallinity in the diffractogram. The corresponding elemental mapping of Mo2C/SCN shows distinct peaks for carbon (41.47%), nitrogen (32.54%), sulfur (1.37%), and molybdenum (24.62%) with no additional impurity peaks, reflecting the successful synthesis. Later, the glassy carbon electrode (GCE) was modified by Mo2C/SCN nano -catalyst for simultaneous sensing of uric acid (UA) and folic acid (FA). The fabricated Mo2C/SCN/GCE is capable of simultaneous and interference free electrochemical detection of UA and FA in a binary mixture. The limit of detection (LOD) calculated at Mo2C/SCN/GCE for UA and FA was 21.5 nM (0.09 - 47.0 mu M) and 14.7 nM (0.09 - 167.25 mu M) respectively by differential pulse voltammetric (DPV) technique. The presence of interferons has no significant effect on the sensor's performance, making it suitable for real sample analysis. The present method can be extended to fabricate an electrochemical sensor for various molecules.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Department of Computer Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choi, Dong-Soo photo

Choi, Dong-Soo
College of Engineering (Department of Computer Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE