Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Assessment of Steel Slag and Steel Fiber to Control Electromagnetic Shielding in High-Strength Concrete

Authors
Yuan, Tian-FengChoi, Jin-SeokKim, Seong-KyumYoon, Young-Soo
Issue Date
Mar-2021
Publisher
KOREAN SOCIETY OF CIVIL ENGINEERS-KSCE
Keywords
Steel slag; Steel fiber; Electrical resistivity; Electromagnetic shielding effectiveness; High-strength concrete
Citation
KSCE JOURNAL OF CIVIL ENGINEERING, v.25, no.3, pp 920 - 930
Pages
11
Journal Title
KSCE JOURNAL OF CIVIL ENGINEERING
Volume
25
Number
3
Start Page
920
End Page
930
URI
https://scholarworks.bwise.kr/kumoh/handle/2020.sw.kumoh/28305
DOI
10.1007/s12205-021-0629-1
ISSN
1976-3808
1226-7988
Abstract
This study investigates the influence of steel slag (SS) and steel fibers on the electrical resistivity and electromagnetic (EM) shielding effectiveness of high-strength concrete (HSC). It was found that the electrical resistivity of mixtures were mainly influenced by free water. Thus, the EM shielding effectiveness was evaluated without the effect of free water. HSC with 20% replacement ratio of SS exhibited slightly improved EM shielding, lower electrical resistivity, and reduced strength (compressive and flexural) compared to HSC without SS. However, HSC with steel fibers exhibited significantly improved EM shielding, lower electrical resistivity, and higher strength and toughness compared to HSC without steel fibers. An increase in the steel fiber content in the HSC significantly decreased the electrical resistivity and increased the shielding effectiveness, strength, and toughness. Regardless of the fiber content in the fiber volume fraction of mixture, the shielding effectiveness is similar for cases with and without SS whose electrical resistivity values differ only slightly. This proves that the EM shielding effectiveness was mainly affected by the electrical resistivity and these properties are significantly correlated when the electrical resistivity values differ noticeably. HSC reinforced with rebar with 50 mm spacing exhibited a 23.5-75.6% increase in the shielding effectiveness in the 600-1,000 MHz frequency region compared to pristine HSC.
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE