Assessing the Seismic Performance of Exterior Precast Concrete Joints with Ultra-High-Performance Fiber-Reinforced Concreteopen access

Authors
Kim, SeungkiShin, JinwonKim, Woosuk
Issue Date
Feb-2024
Publisher
SPRINGER
Keywords
Seismic performance; Precast concrete joints; Fiber; Ultra-high-performance fiber-reinforced concrete
Citation
INTERNATIONAL JOURNAL OF CONCRETE STRUCTURES AND MATERIALS, v.18, no.1
Journal Title
INTERNATIONAL JOURNAL OF CONCRETE STRUCTURES AND MATERIALS
Volume
18
Number
1
URI
https://scholarworks.bwise.kr/kumoh/handle/2020.sw.kumoh/28494
DOI
10.1186/s40069-023-00646-9
ISSN
1976-0485
2234-1315
Abstract
This study was conducted to evaluate the seismic performance of an exterior precast concrete (PC) beam-column joint with ultra-high-performance fiber-reinforced concrete (UHPFRC). Currently, 45 MPa non-shrinkage mortar is used as grouting for the connection between PC beams and columns. In this study, PC joint specimens were designed using 45 MPa non-shrinkage mortar and 120 MPa UHPFRC as a grouting agent for connecting PC members. The shear reinforcement effect of UHPFRC was confirmed to reduce shear cracks in the joint core; this trend was similar in the specimens with reduced shear rebars. The maximum moment of the test specimen with the corbel was slightly increased, but there was no significant difference, and the failure pattern also showed similar results to the specimen without the corbel. In the test specimen to which the U-shaped beam was applied, the attachment surface of ultra-high-performance concrete and normal concrete were separated, and a large decrease in strength was observed. Considering workability, U-shaped beam do not seem to have any major merits in general, such as increased strength and difficulty in manufacturing, and it was judged that it was effective to separate the PC beams from the column face through corbels. Shear reinforcement through UHPFRC is effective in relieving congestion by reducing shear reinforcement bars at the joint, and it is judged that it can be used as PC joint grouting due to its excellent fluidity.
Files in This Item
There are no files associated with this item.
Appears in
Collections
School of Architecture > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Woosuk photo

Kim, Woosuk
College of Engineering (School of Architecture)
Read more

Altmetrics

Total Views & Downloads

BROWSE