Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

탈수슬러지의 마이크로웨이브와 증기 건조공정의 성능비교Comparison of microwave and steam-type drying processes for dehydrated sludge in a wastewater treatment plant

Other Titles
Comparison of microwave and steam-type drying processes for dehydrated sludge in a wastewater treatment plant
Authors
정상홍최윤성이승환
Issue Date
Jun-2024
Publisher
대한상하수도학회
Keywords
슬러지; 마이크로웨이브; 증기; 유지관리; 효율성; Sludge; Microwave; Steam; Maintenance; Efficiency
Citation
상하수도학회지, v.38, no.3, pp 155 - 164
Pages
10
Journal Title
상하수도학회지
Volume
38
Number
3
Start Page
155
End Page
164
URI
https://scholarworks.bwise.kr/kumoh/handle/2020.sw.kumoh/28742
ISSN
1225-7672
2287-822X
Abstract
There are two primary sludge drying methods such as the direct heating microwave method and the indirect heating steam one. In this study, the drying treatment facility at sewage treatment plant A applied both of these drying methods. The research aimed to investigate the optimal operation approach for the drying facility, considering the input sludge and the moisture content data after the drying process. Moisture content and removal rate data were executed at the research facility from January 2016 to December 2018. First, the microwave, a direct heating drying method, performed intensive drying only on the outer surface of the sludge by directly applying heat to the sludge using far infrared rays, so effective sludge drying was not achieved. On the other hand, the steam method of the indirect heating method used steam from a gas boiler to maximize the utilization of the heat transfer area and reduce energy of the dryer, resulting in an effective sludge drying efficiency. The sludge moisture content brought into the sludge drying facility was about 80%, but the moisture content of the sludge that went through the drying facility was less than 10% of the design standard. Therefore, the steam method of the indirect heating method is more effective than the microwave method of the previous direct heating method and is more effective for maintenance It has proven that it is an efficient method of operating construction facilities.
Files in This Item
Go to Link
Appears in
Collections
Department of Environmental Engineering > 1. Journal Articles

qrcode